Medial Collateral Ligament Reconstruction With Dual Adjustable-Loop Suspensory Fixation: A Technique Guide

Arthrosc Tech. 2021 Feb 2;10(3):e621-e628. doi: 10.1016/j.eats.2020.10.049. eCollection 2021 Mar.

Abstract

The purpose of this technique paper is to outline a minimally invasive technique using dual suspensory fixation with adjustable-loop devices for reconstruction of the superficial medial collateral ligament. The femoral fixation is performed through a limited approach at the anatomic origin of the medial collateral ligament, a socket is prepared, and the graft is docked using the adjustable-loop suspensory fixation. The tibial socket is prepared through a separate incision just distal to the pes anserine tendons and drilled medially to laterally perpendicular to the tibial shaft. The graft is tunneled and docked into the tibial tunnel using adjustable-loop cortical suspensory fixation on the far cortex. The knee is cycled through a full arc of motion and stressed in valgus to take initial creep out of the construct. The knee is placed in 30° of flexion and slight varus and final tension is applied to both the femoral and tibial side. With this technique, fixation can be completed with a minimally invasive incision and it allows the ability to tension the graft both on the femoral and tibial side to the desired level, providing a significant advantage over previously used interference screw techniques.