A Printed Paper-Based Anion Sensor Array for Multi-Analyte Classification: On-Site Quantification of Glyphosate

Chempluschem. 2021 Jun;86(6):798-802. doi: 10.1002/cplu.202100041. Epub 2021 Mar 31.

Abstract

We report a paper-based chemosensor array device (PCSAD) for the quantitative detection of oxyanions including the herbicide glyphosate (GlyP) in aqueous media. The mechanism of the oxyanion detection relies on a coordination-binding-based sensor array. In this study, the competitive coordination binding among Zn2+ , four catechol dyes, and seven oxyanions caused noticeable colour changes. The colour changes were employed for qualitative and quantitative analyses using an in-house automated image-processing algorithm with pattern recognition for digital images. A linear discrimination analysis discerned similarly structured oxyanions with 100 % accuracy. The regression analysis allowed the accurate quantification of GlyP in the herbicide products with a limit of detection of 16 mg/L, which is lower than the health advisory value for children (20 mg/L) stipulated by the environmental protection agency (EPA). PCSAD is a powerful sensor device for the on-site quantification of aqueous anions for environmental assessment.

Keywords: anions; chemosensor arrays; herbicides; image processing; paper.

Publication types

  • Research Support, Non-U.S. Gov't