Strain Elastography of Injured Equine Superficial Digital Flexor Tendons: A Reliability Study of Manual Measurements

Animals (Basel). 2021 Mar 12;11(3):795. doi: 10.3390/ani11030795.

Abstract

Early diagnosis of tendon injuries and accurate long-term monitoring of the healing process are key for equine veterinarians that use conventional ultrasonography. The development of strain elastography could improve the management of clinical cases. The aim of the study was to assess the intraobserver repeatability and interobserver reproducibility of manual measurements of the colored areas of the tendons within elastograms and to standardize this manual modality by comparing the analysis of the images with ImageJ. Twenty elastograms of the injured superficial digital flexor tendons (SDFTs) of horses were analyzed by two different operators after an acute injury was diagnosed with ultrasonography. Statistical analysis demonstrated excellent intraobserver repeatability (intraclass correlation coefficient, ICC = 0.949) and good interobserver reproducibility (ICC = 0.855) for manual measurements performed with tools available on the ultrasound unit. A good agreement between manual measurements and measurements performed with ImageJ (ICC = 0.849) was then demonstrated. Despite its subjectivity, the manual modality proved to be a valid method for analyzing images obtained with strain elastography.

Keywords: ImageJ; SDFT; horse; manual measurement; reliability; strain elastography.