Continuous oxygen saturation monitoring during cardiac catheterization in adults
- PMID: 3383653
- DOI: 10.1378/chest.94.1.28
Continuous oxygen saturation monitoring during cardiac catheterization in adults
Abstract
Arterial hypoxemia may contribute to morbidity during cardiac catheterization. Therefore, we measured arterial hemoglobin oxygen saturation (SaO2) continuously using pulse oximetry in 29 patients (age range, 21 to 83 years) undergoing cardiac catheterization. Baseline SaO2 was 96 +/- 0.4 percent. All patients had a decrease in SaO2 at some time during the procedure. Eleven patients (38 percent) had episodes of arterial hypoxemia, defined as a decrease in SaO2 below 90 percent. In these 11 patients, the mean number of episodes of hypoxemia was 16 +/- 7, and the mean duration of each episode was 53 +/- 25 seconds. Multiple stepwise regression analysis showed that the minimum SaO2 during catheterization for any patient was significantly associated with the baseline SaO2, duration of the procedure, and end-diastolic volume (EDV) as described by the following regression equation: minimum SaO2 = 46.8 - 0.0580 (duration of procedure in minutes) + 0.5362 (baseline SaO2) - 0.0159 (EDV). Based on our finding of arterial hypoxemia in greater than one third of our patients, we would consider continuous SaO2 monitoring or supplemental oxygen during cardiac catheterization, especially for those patients with poor ventricular function or low resting SaO2 or those expected to have long procedures.
Similar articles
-
Should all patients undergoing cardiac catheterization or percutaneous transluminal coronary angioplasty receive oxygen?Chest. 1994 Mar;105(3):727-32. doi: 10.1378/chest.105.3.727. Chest. 1994. PMID: 8131533 Clinical Trial.
-
Cerebral Oxygen Saturation in Children With Congenital Heart Disease and Chronic Hypoxemia.Anesth Analg. 2017 Jul;125(1):234-240. doi: 10.1213/ANE.0000000000002073. Anesth Analg. 2017. PMID: 28514318 Free PMC article.
-
Accuracy of calculated arterial saturation in oxygen in neonatal foals and effects of monitor, sensor, site of sensor placement, and degree of hypoxemia on the accuracy of pulse oximetry.J Vet Emerg Crit Care (San Antonio). 2014 Sep-Oct;24(5):529-35. doi: 10.1111/vec.12231. Epub 2014 Sep 11. J Vet Emerg Crit Care (San Antonio). 2014. PMID: 25212699
-
Pulse oximetry for hypoxemia: a warning to users and manufacturers.Intensive Care Med. 1989;15(8):540-2. doi: 10.1007/BF00273571. Intensive Care Med. 1989. PMID: 2691541 Review.
-
[Development of pulse oximetry].Nihon Kyobu Shikkan Gakkai Zasshi. 1994 Dec;32 Suppl:96-100. Nihon Kyobu Shikkan Gakkai Zasshi. 1994. PMID: 7602851 Review. Japanese.
Cited by
-
Pulse oximetry.J Clin Monit. 1989 Jan;5(1):37-62. doi: 10.1007/BF01618369. J Clin Monit. 1989. PMID: 2647912 Review.
MeSH terms
LinkOut - more resources
Full Text Sources