[Interstitial gamma irradiation of the parasternal area in breast cancer]

Med Radiol (Mosk). 1988 Jun;33(6):44-9.
[Article in Russian]

Abstract

The authors substantiated the effectiveness of local irradiation of the parasternal lymph node chain by means of cylindrical 60Co sources of original design. Sizes of the sources: total length--65 mm, active length--60 mm, external diameter--1 mm. This type of irradiation as part of combined and multimodality therapy was used in 112 patients. This method is easy to perform and well tolerated by patients.

MeSH terms

  • Brachytherapy / methods*
  • Breast Neoplasms / diagnostic imaging
  • Breast Neoplasms / radiotherapy*
  • Catheterization / instrumentation
  • Catheterization / methods
  • Cobalt Radioisotopes / administration & dosage*
  • Combined Modality Therapy
  • Female
  • Humans
  • Ligation / methods
  • Lymphatic Metastasis
  • Postoperative Care
  • Radiography
  • Radiotherapy Dosage
  • Sternum
  • Thoracic Arteries / surgery

Substances

  • Cobalt Radioisotopes