A New Active Osseointegrated Implant System in Patients with Single-Sided Deafness
- PMID: 33902037
- DOI: 10.1159/000515489
A New Active Osseointegrated Implant System in Patients with Single-Sided Deafness
Abstract
Objective: The Cochlear™ Osia® System (Osia) is an active transcutaneous bone conduction implant system intended for patients with conductive and mixed hearing loss but can also be used in cases of single-sided deafness (SSD) for the contralateral routing of signal (CROS). The Osia implant is placed subcutaneously under the intact skin behind the ear with the piezoelectric actuator connected to an osseointegrated BI300 implant - a titanium screw used for a 2-stage Baha surgery - on the mastoid. The external processor is magnetically attached to the subcutaneous implant receiver coil. As the Osia has recently been CE certified and is new on the market, with limited patient outcome data for SSD available, the objective of this study was the evaluation of surgical procedure, audiological results, and patient satisfaction for the Osia in SSD patients.
Study design: In a prospective, monocentric clinical observation study, 6 patients (18 years of age or older) with SSD and bone conduction thresholds pure tone average 0.5, 1, 2, and 4 kHz ≤25 dB HL on the contralateral side were implanted with an Osia. Analysis of clinical outcome data with respect to surgical technique, adverse events, audiological measurement, and subjective benefit for SSD patients was conducted. Audiological measurements performed included hearing thresholds, sound field thresholds, word recognition scores (WRS; in %) in quiet, and speech recognition thresholds in noise (in dB SNR). All tests were performed unaided and aided with the Osia. The subjective benefit with the Osia was determined by using 2 questionnaires; the Abbreviated Profile of Hearing Aid Benefit (APHAB) and the Bern Benefit in Single-Sided Deafness (BBSSD).
Results: Preliminary results indicate a straightforward surgical procedure with a low rate of complications and an improvement in speech perception in quiet, listening performance in everyday situations and patient satisfaction. However, in one of 6 subjects, a revision surgery had to be performed.
Conclusion: Provided that SSD patients are open for CROS hearing, they can benefit from the Osia by reduced head shadow effects and better speech recognition. Special caution should be given to the skin at the site of implantation to avoid complications.
Keywords: Active bone conduction implant; Contralateral routing of signal; Osia; Single-sided deafness; Transcutaneous.
© 2021 The Author(s) Published by S. Karger AG, Basel.
Similar articles
-
Long-term data of the new transcutaneous partially implantable bone conduction hearing system Osia®.Eur Arch Otorhinolaryngol. 2022 Sep;279(9):4279-4288. doi: 10.1007/s00405-021-07167-9. Epub 2021 Nov 18. Eur Arch Otorhinolaryngol. 2022. PMID: 34792628 Free PMC article.
-
Audiological and clinical outcomes of a transcutaneous bone conduction hearing implant: Six-month results from a multicentre study.Clin Otolaryngol. 2019 Mar;44(2):144-157. doi: 10.1111/coa.13248. Epub 2018 Nov 18. Clin Otolaryngol. 2019. PMID: 30358920
-
Clinical performance, audiological outcomes, and quality of life of the Cochlear Osia ® system.Am J Otolaryngol. 2023 Sep-Oct;44(5):103951. doi: 10.1016/j.amjoto.2023.103951. Epub 2023 Jun 12. Am J Otolaryngol. 2023. PMID: 37329694
-
Multicentric study on surgical information and early safety and performance results with the Bonebridge BCI 602: an active transcutaneous bone conduction hearing implant.Eur Arch Otorhinolaryngol. 2023 Apr;280(4):1565-1579. doi: 10.1007/s00405-022-07792-y. Epub 2023 Jan 10. Eur Arch Otorhinolaryngol. 2023. PMID: 36625869 Free PMC article. Review.
-
Systematic Review and Meta-Analysis of a New Active Transcutaneous Bone Conduction Implant.Laryngoscope. 2024 Apr;134(4):1531-1539. doi: 10.1002/lary.31053. Epub 2023 Sep 18. Laryngoscope. 2024. PMID: 37721219 Review.
Cited by
-
Clinical performance, safety, and patient-reported outcomes of an active osseointegrated bone-conduction hearing implant system at 24-month follow-up.Eur Arch Otorhinolaryngol. 2024 Feb;281(2):683-691. doi: 10.1007/s00405-023-08133-3. Epub 2023 Aug 8. Eur Arch Otorhinolaryngol. 2024. PMID: 37552281 Free PMC article.
-
Electro-vibrational stimulation results in improved speech perception in noise for cochlear implant users with bilateral residual hearing.Sci Rep. 2023 Jul 12;13(1):11251. doi: 10.1038/s41598-023-38468-0. Sci Rep. 2023. PMID: 37438474 Free PMC article.
-
An objective bone conduction verification tool using a piezoelectric thin-film force transducer.Front Neurosci. 2022 Nov 17;16:1068682. doi: 10.3389/fnins.2022.1068682. eCollection 2022. Front Neurosci. 2022. PMID: 36466173 Free PMC article.
-
Long-term data of the new transcutaneous partially implantable bone conduction hearing system Osia®.Eur Arch Otorhinolaryngol. 2022 Sep;279(9):4279-4288. doi: 10.1007/s00405-021-07167-9. Epub 2021 Nov 18. Eur Arch Otorhinolaryngol. 2022. PMID: 34792628 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials
Miscellaneous
