Purpose: To present a surgical technique that allows rescue (repositioning) of a dislocated Crystalens model intraocular lens using scleral sutures.
Methods: The surgical technique is described with supplemental video.
Results: The technique was used in one patient with 3 months of follow-up information. The intraocular lens was well-positioned, and the visual acuity is 20/20, without adverse events.
Conclusion: Scleral suture techniques for repositioning of the Crystalens offer a suitable alternative to intraocular lens exchange.