Endoscopic Ultrasound-guided Fine-needle Biopsy With or Without Rapid On-site Evaluation for Diagnosis of Solid Pancreatic Lesions: A Randomized Controlled Non-Inferiority Trial

Gastroenterology. 2021 Sep;161(3):899-909.e5. doi: 10.1053/j.gastro.2021.06.005. Epub 2021 Jun 9.

Abstract

Background and aims: The benefit of rapid on-site evaluation (ROSE) on the diagnostic accuracy of endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) has never been evaluated in a randomized study. This trial aimed to test the hypothesis that in solid pancreatic lesions (SPLs), diagnostic accuracy of EUS-FNB without ROSE was not inferior to that of EUS-FNB with ROSE.

Methods: A noninferiority study (noninferiority margin, 5%) was conducted at 14 centers in 8 countries. Patients with SPLs requiring tissue sampling were randomly assigned (1:1) to undergo EUS-FNB with or without ROSE using new-generation FNB needles. The touch-imprint cytology technique was used to perform ROSE. The primary endpoint was diagnostic accuracy, and secondary endpoints were safety, tissue core procurement, specimen quality, and sampling procedural time.

Results: Eight hundred patients were randomized over an 18-month period, and 771 were analyzed (385 with ROSE and 386 without). Comparable diagnostic accuracies were obtained in both arms (96.4% with ROSE and 97.4% without ROSE, P = .396). Noninferiority of EUS-FNB without ROSE was confirmed with an absolute risk difference of 1.0% (1-sided 90% confidence interval, -1.1% to 3.1%; noninferiority P < .001). Safety and sample quality of histologic specimens were similar in both groups. A significantly higher tissue core rate was obtained by EUS-FNB without ROSE (70.7% vs. 78.0%, P = .021), with a significantly shorter mean sampling procedural time (17.9 ± 8.8 vs 11.7 ± 6.0 minutes, P < .0001).

Conclusions: EUS-FNB demonstrated high diagnostic accuracy in evaluating SPLs independently on execution of ROSE. When new-generation FNB needles are used, ROSE should not be routinely recommended. (ClinicalTrial.gov number NCT03322592.).

Keywords: Diagnostic Accuracy; Endoscopic Ultrasound Tissue Acquisition; Pancreatic Cancer; Preoperative Sampling.

Publication types

  • Comparative Study
  • Equivalence Trial
  • Multicenter Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Endoscopic Ultrasound-Guided Fine Needle Aspiration* / instrumentation
  • Female
  • Humans
  • Male
  • Middle Aged
  • Pancreatic Neoplasms / pathology*
  • Predictive Value of Tests
  • Prospective Studies
  • Rapid On-site Evaluation*
  • Reproducibility of Results

Associated data

  • ClinicalTrials.gov/NCT03322592