Evaluation of external contamination on the vial surfaces of some hazardous drugs that commonly used in Chinese hospitals and comparison between environmental contamination generated during robotic compounding by IV: Dispensing robot vs. manual compounding in biological safety cabinet

J Oncol Pharm Pract. 2022 Oct;28(7):1487-1498. doi: 10.1177/10781552211023571. Epub 2021 Jun 24.

Abstract

Objectives: The aims of the study were to evaluate the external contamination of hazardous drug vials used in Chinese hospitals and to compare environmental contamination generated by a robotic intelligent dispensing system (WEINAS) and a manual compounding procedure using a biological safety cabinet (BSC).

Methods: Cyclophosphamide, fluorouracil, and gemcitabine were selected as the representative hazardous drugs to monitor surface contamination of vials. In the comparative analysis of environmental contamination from manual and robotic compounding, wipe samples were taken from infusion bags, gloves, and the different locations of the BSC and the WEINAS robotic system. In this study, high-performance liquid chromatography coupled with double mass spectrometer (HPLC-MS/MS) was employed for sample analysis.

Results: (1) External contamination was measured on vials of all three hazardous drugs. The contamination detected on fluorouracil vials was the highest with an average amount up to 904.33 ng/vial, followed by cyclophosphamide (43.51 ng/vial), and gemcitabine (unprotected vials of 5.92 ng/vial, protected vials of 0.66 ng/vial); (2) overall, the environmental contamination induced by WEINAS robotic compounding was significantly reduced compared to that by manual compounding inside the BSC. Particularly, compared with manual compounding, the surface contamination on the infusion bags during robotic compounding was nearly nine times lower for cyclophosphamide (10.62 ng/cm2 vs 90.43 ng/cm2), two times lower for fluorouracil (3.47 vs 7.52 ng/cm2), and more than 23 times lower for gemcitabine (2.61 ng/cm2 vs 62.28 ng/cm2).

Conclusions: The external contamination occurred extensively on some hazardous drug vials that commonly used in Chinese hospitals. Comparison analysis for both compounding procedures revealed that robotic compounding can remarkably reduce environmental contamination.

Keywords: Hazardous drugs; biological safety cabinet; drug contamination; occupational exposure; robotic system.

MeSH terms

  • Antineoplastic Agents* / analysis
  • China
  • Cyclophosphamide / analysis
  • Drug Compounding
  • Environmental Monitoring / methods
  • Equipment Contamination / prevention & control
  • Fluorouracil / analysis
  • Hospitals
  • Humans
  • Occupational Exposure* / analysis
  • Occupational Exposure* / prevention & control
  • Robotic Surgical Procedures*
  • Robotics* / methods
  • Tandem Mass Spectrometry

Substances

  • Antineoplastic Agents
  • Cyclophosphamide
  • Fluorouracil