Comparison of the two techniques for involutional lower eyelid entropion: A retrospective study

J Craniomaxillofac Surg. 2021 Nov;49(11):1005-1009. doi: 10.1016/j.jcms.2021.06.010. Epub 2021 Jun 19.

Abstract

Evaluation of the surgical outcome and the patient satisfaction between the modified Wies technique and the Jones retractor plication technique for involutional lower eyelid entropion without horizontal eyelid laxity. Patients who underwent the modified Wies technique (group 1) and the Jones retractor plication technique (group 2) for correction of involutional lower eyelid entropion without horizontal eyelid laxity between January 2014 and January 2020 were retrospectively reviewed. Patients with horizontal eyelid laxity; cicatricial, congenital or iatrogenic entropion; and less than 6 months of follow-up time were excluded. The main outcome measures were the recurrence rate, correct anatomical position of the eyelid, symptom relief, and postoperative complications for both groups. 37 patients (41 eyes) in Group 1 and 34 patients (34 eyes) in Group 2 were enrolled in the study. Mean age ± SD was 75.6 ± 8.5 years in Group 1 and 73.4 ± 7.9 years in Group 2 (p:0.255). The mean follow-up time (range) was 24.3 (6-80) months in group 1 and 25.3 (6-78) months in group 2 (p:0.818). Two patients in Group 1 and seven patients in Group 2 had a recurrence during the follow-up period (p:0.07). Based on the results of the study, it seems that the modified Wies technique may be a good alternative in suitable patients, as it has satisfactory surgical results.

Keywords: Involutional entropion; Jones retractor plication; Modified wies technique; Recurrence rate.

MeSH terms

  • Entropion* / surgery
  • Eyelids / surgery
  • Follow-Up Studies
  • Humans
  • Retrospective Studies
  • Suture Techniques