Electrotonic parameters of cat spinal alpha-motoneurons evaluated with an equivalent cylinder model that incorporates non-uniform membrane resistivity

Brain Res. 1987 Dec 1;435(1-2):398-402. doi: 10.1016/0006-8993(87)91633-7.

Abstract

The membrane voltage transients in response to constant intracellular current steps were analyzed in cat spinal alpha-motoneurons, using an equivalent cylinder model extended to include spatial non-uniformity in membrane resistivity. The main hypothesis was that the soma membrane resistivity did not differ significantly from the dendritic membrane resistivity. Evidence was found that the uniform-resistance cylinder model cannot be applied to motoneurons on the basis of inconsistencies in calculations of electrotonic length. Assuming a constant membrane capacitance, the membrane resistivity of the dendrites was found to be 500 times that of the soma. We conclude that there is a considerable difference in the membrane resistivity between the soma and dendrites of motoneurons, and that uniform-resistance models should not be applied to spinal alpha-motoneurons.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Cats
  • Electric Stimulation
  • Femoral Nerve / physiology
  • Membrane Potentials
  • Models, Neurological
  • Motor Neurons / physiology*
  • Spinal Cord / physiology*