. 2021 Oct 1;4(10):e2128802.
doi: 10.1001/jamanetworkopen.2021.28802.

D-Dimer Testing for the Exclusion of Pulmonary Embolism Among Hospitalized Patients With COVID-19

Affiliations

D-Dimer Testing for the Exclusion of Pulmonary Embolism Among Hospitalized Patients With COVID-19

Constantine N Logothetis et al. JAMA Netw Open. .

Abstract

This prognostic study evaluates the use of plasma D-dimer concentrations to rule out pulmonary embolism among patients hospitalized with COVID-19.

PubMed Disclaimer

Conflict of interest statement

Conflict of Interest Disclosures: None declared.

Figures

Figure.
Figure.. Receiver Operator Characteristic Curve for Plasma D-Dimer Concentrations in μg/mL
The receiver operator characteristic curve of plasma D-dimer concentration to classify pulmonary embolism diagnosed by computed tomographic pulmonary angiography at all values of plasma D-dimer in micrograms per milliliter is presented. The performance characteristics at all observed D-dimer concentrations (blue dots), a smoothed, parametric estimation function (solid line), and an uninformative hypothetical test (dashed line) are presented. AUC indicates area under the curve.

Similar articles

Cited by

References

    1. Konstantinides SV, Barco S, Lankeit M, Meyer G. Management of pulmonary embolism: an update. J Am Coll Cardiol. 2016;67(8):976-990. doi:10.1016/j.jacc.2015.11.061 - DOI - PubMed
    1. van Es N, Kraaijpoel N, Klok FA, et al. . The original and simplified Wells rules and age-adjusted D-dimer testing to rule out pulmonary embolism: an individual patient data meta-analysis. J Thromb Haemost. 2017;15(4):678-684. doi:10.1111/jth.13630 - DOI - PubMed
    1. Docherty AB, Harrison EM, Green CA, et al. ; ISARIC4C investigators . Features of 20 133 UK patients in hospital with COVID-19 using the ISARIC WHO Clinical Characterisation Protocol: prospective observational cohort study. BMJ. 2020;369:m1985. doi:10.1136/bmj.m1985 - DOI - PMC - PubMed
    1. Abou-Ismail MY, Diamond A, Kapoor S, Arafah Y, Nayak L. The hypercoagulable state in COVID-19: incidence, pathophysiology, and management. Thromb Res. 2020;194:101-115. doi:10.1016/j.thromres.2020.06.029 - DOI - PMC - PubMed
    1. Righini M, Van Es J, Den Exter PL, et al. . Age-adjusted D-dimer cutoff levels to rule out pulmonary embolism: the ADJUST-PE study. JAMA. 2014;311(11):1117-1124. doi:10.1001/jama.2014.2135 - DOI - PubMed