Corrosion of titanium under simulated inflammation conditions: clinical context and in vitro investigations
- PMID: 34626820
- DOI: 10.1016/j.actbio.2021.10.002
Corrosion of titanium under simulated inflammation conditions: clinical context and in vitro investigations
Abstract
Titanium and alloys thereof are widely utilized for biomedical applications in the fields of orthopedics and dentistry. The corrosion resistance and perceived biocompatibility of such materials are essentially related to the presence of a thin passive oxide layer on the surface. However, during inflammation phases, the immune system and its leukocytic cells generate highly aggressive molecules, such as hydrogen peroxide and radicals, that can significantly alter the passive film resulting in the degradation of the titanium implants. In combination with mechanical factors, this can lead to the release of metal ions, nanoparticles or microscaled debris in the surrounding tissues (which may sustain chronic inflammation), bring about relevant health issues and contribute to implant loss or failure. After briefly presenting the context of inflammation, this review article analyses the state-of-the-art knowledge of the in vitro corrosion of titanium, titanium alloys and coated titanium by reactive oxygen species and by living cells with an emphasis on electrochemical and microstructural aspects. STATEMENT OF SIGNIFICANCE: Inflammation involves the production of reactive oxygen species that are known to alter the passive layer protecting titanium implants against the aggressive environment of the human body. Inflammatory processes therefore contribute to the deterioration of biomedical devices. Although review articles on biomaterials for implant applications are regularly published in the literature, none has ever focused specifically on the topic of inflammation. After briefly recalling the clinical context, this review analyses the in vitro studies on titanium corrosion under simulated inflammation conditions from the pioneer works of the 80s and the 90s till the most recent investigations. It reports about the status of this research area for a multidisciplinary readership covering the fields of materials science, corrosion and implantology.
Keywords: Corrosion; Implants; Inflammation; Reactive oxygen species; Titanium.
Copyright © 2021. Published by Elsevier Ltd.
Conflict of interest statement
Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. The authors declare the following financial interests/personal relationships which may be considered as potential competing interests:
Similar articles
-
An electrochemical impedance investigation of the behaviour of anodically oxidised titanium in human plasma and cognate fluids, relevant to dental applications.J Mater Sci Mater Med. 2008 Nov;19(11):3443-53. doi: 10.1007/s10856-008-3487-1. Epub 2008 Jun 27. J Mater Sci Mater Med. 2008. PMID: 18584125
-
Determinants of corrosion resistance of Ti-6Al-4V alloy dental implants in an In Vitro model of peri-implant inflammation.PLoS One. 2019 Jan 31;14(1):e0210530. doi: 10.1371/journal.pone.0210530. eCollection 2019. PLoS One. 2019. PMID: 30703125 Free PMC article.
-
Evaluation of mechanical properties, in vitro corrosion resistance and biocompatibility of Gum Metal in the context of implant applications.J Mech Behav Biomed Mater. 2021 Mar;115:104289. doi: 10.1016/j.jmbbm.2020.104289. Epub 2020 Dec 24. J Mech Behav Biomed Mater. 2021. PMID: 33388535
-
Corrosion and surface modification on biocompatible metals: A review.Mater Sci Eng C Mater Biol Appl. 2017 Aug 1;77:1261-1274. doi: 10.1016/j.msec.2017.04.102. Epub 2017 Apr 20. Mater Sci Eng C Mater Biol Appl. 2017. PMID: 28532004 Review.
-
An overview of the corrosion aspect of dental implants (titanium and its alloys).Indian J Dent Res. 2009 Jan-Mar;20(1):91-8. doi: 10.4103/0970-9290.49068. Indian J Dent Res. 2009. PMID: 19336868 Review.
Cited by
-
Fretting and Fretting Corrosion Behavior of Additively Manufactured Ti-6Al-4V and Ti-Nb-Zr Alloys in Air and Physiological Solutions.J Funct Biomater. 2024 Feb 5;15(2):38. doi: 10.3390/jfb15020038. J Funct Biomater. 2024. PMID: 38391891 Free PMC article.
-
Antibiofilm peptides enhance the corrosion resistance of titanium in the presence of Streptococcus mutans.Front Bioeng Biotechnol. 2024 Jan 10;11:1339912. doi: 10.3389/fbioe.2023.1339912. eCollection 2023. Front Bioeng Biotechnol. 2024. PMID: 38274010 Free PMC article.
-
Surface-modified titanium and titanium-based alloys for improved osteogenesis: A critical review.Heliyon. 2023 Dec 18;10(1):e23779. doi: 10.1016/j.heliyon.2023.e23779. eCollection 2024 Jan 15. Heliyon. 2023. PMID: 38223705 Free PMC article. Review.
-
Mettl3‑mediated m6A RNA methylation regulates osteolysis induced by titanium particles.Mol Med Rep. 2024 Mar;29(3):36. doi: 10.3892/mmr.2024.13160. Epub 2024 Jan 12. Mol Med Rep. 2024. PMID: 38214327 Free PMC article.
-
Malignant Neoplasms Arising in the Cardiac Pacemaker Cavity: A Systematic Review.Cancers (Basel). 2023 Oct 29;15(21):5206. doi: 10.3390/cancers15215206. Cancers (Basel). 2023. PMID: 37958380 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials