Pragmatic role of noncontrast magnetic resonance lymphangiography in postoperative chylothorax or cervical chylous leakage as a diagnostic and preprocedural planning tool

Eur Radiol. 2022 Apr;32(4):2149-2157. doi: 10.1007/s00330-021-08342-6. Epub 2021 Oct 26.

Abstract

Objectives: To define the roles of noncontrast magnetic resonance lymphangiography (MRL) in the management of postoperative chylothorax or cervical chylous leakage.

Methods: A total of 50 consecutive patients underwent noncontrast MRL, intranodal lymphangiography, and thoracic duct embolization between May 2016 and April 2020. Their mean age was 62.6 years ± 10.3 (SD) years, and 35 of the participants were men. Conventional lymphangiographic images were sufficient in quality as a reference for the evaluation of diagnostic accuracy of leakage and location in 35 patients (70%) and for evaluation of anatomic details of the thoracic duct and jugulovenous junction in 34 patients (68%).

Results: MRL showed that the sensitivity, specificity, and positive and negative predictive values for leakage detection were 100%, 97.1%, 100%, and 100%, respectively, and the concordance rate was 97.14% (95% confidence interval [CI], 85.08-99.93%; p < .001). Leakage location was concordant between MRL and conventional lymphangiography in 27 patients (77.1%, 27/35). Regarding anatomical details of the thoracic duct, variation of the thoracic duct was missed in 11.7% of patients (4/34). The jugulovenous junction was observed in 91.1% (31/34), and its opening into the central vein was depicted in 76.4% (26/34). The concordance rate was between 76.47 and 91.18.

Conclusions: Noncontrast MRL has a high sensitivity for the detection of postoperative thoracic and cervical chylous leakage but is suboptimal for the localization of the leak and depiction of anatomical details of the thoracic duct. This method is worthy of consideration as either a decision-making or planning tool for subsequent interventions.

Key points: • Noncontrast MRL provides limited resolution images of CLS but has a high sensitivity for the detection of postoperative chylous leakage in the thoracic and neck regions. • Noncontrast MRL is suboptimal for depicting anatomic details in the thoracic duct and jugulovenous junction but can play a role as a decision-making and a planning tool for subsequent lymphatic interventions.

Keywords: Chylothorax; Embolization, therapeutic; Lymphography; Magnetic resonance imaging; Thoracic duct.

MeSH terms

  • Chylothorax* / diagnostic imaging
  • Chylothorax* / pathology
  • Chylothorax* / therapy
  • Embolization, Therapeutic* / methods
  • Humans
  • Lymphography / methods
  • Magnetic Resonance Imaging / methods
  • Magnetic Resonance Spectroscopy
  • Male
  • Middle Aged
  • Thoracic Duct / diagnostic imaging
  • Thoracic Duct / surgery