Comparative diagnostic performance of ultrasound shear wave elastography and magnetic resonance elastography for classifying fibrosis stage in adults with biopsy-proven nonalcoholic fatty liver disease

Eur Radiol. 2022 Apr;32(4):2457-2469. doi: 10.1007/s00330-021-08369-9. Epub 2021 Dec 2.

Abstract

Objectives: To compare the diagnostic accuracy of US shear wave elastography (SWE) and magnetic resonance elastography (MRE) for classifying fibrosis stage in patients with nonalcoholic fatty liver disease (NAFLD).

Methods: Patients from a prospective single-center cohort with clinical liver biopsy for known or suspected NAFLD underwent contemporaneous SWE and MRE. AUCs for classifying biopsy-determined liver fibrosis stages ≥ 1, ≥ 2, ≥ 3, and = 4, and their respective performance parameters at cutoffs providing ≥ 90% sensitivity or specificity were compared between SWE and MRE.

Results: In total, 100 patients (mean age, 51.8 ± 12.9 years; 46% males; mean BMI 31.6 ± 4.7 kg/m2) with fibrosis stage distribution (stage 0/1/2/3/4) of 43, 36, 5, 10, and 6%, respectively, were included. AUCs (and 95% CIs) for SWE and MRE were 0.65 (0.54-0.76) and 0.81 (0.72-0.89), 0.81 (0.71-0.91) and 0.94 (0.89-1.00), 0.85 (0.74-0.96) and 0.95 (0.89-1.00), and 0.91 (0.79-1.00) and 0.92 (0.83-1.00), for detecting fibrosis stage ≥ 1, ≥ 2, ≥ 3, and = 4, respectively. The differences were significant for detecting fibrosis stage ≥ 1 and ≥ 2 (p < 0.01) but not otherwise. At ≥ 90% sensitivity cutoff, MRE yielded higher specificity than SWE at diagnosing fibrosis stage ≥ 1, ≥ 2, and ≥ 3. At ≥ 90% specificity cutoff, MRE yielded higher sensitivity than SWE at diagnosing fibrosis stage ≥ 1 and ≥ 2.

Conclusions: In adults with NAFLD, MRE was more accurate than SWE in diagnosing stage ≥ 1 and ≥ 2 fibrosis, but not stage ≥ 3 or 4 fibrosis.

Key points: • For detecting any fibrosis or mild fibrosis, MR elastography was significantly more accurate than shear wave elastography. • For detecting advanced fibrosis and cirrhosis, MRE and SWE did not differ significantly in accuracy. • For excluding advanced fibrosis and potentially ruling out the need for biopsy, SWE and MRE did not differ significantly in negative predictive value. • Neither SWE nor MRE had sufficiently high positive predictive value to rule in advanced fibrosis.

Keywords: Elasticity imaging techniques; Magnetic resonance elastography; Nonalcoholic fatty liver disease; Sonoelastography.

MeSH terms

  • Adult
  • Biopsy
  • Elasticity Imaging Techniques*
  • Female
  • Fibrosis
  • Humans
  • Liver / diagnostic imaging
  • Liver / pathology
  • Liver Cirrhosis / pathology
  • Male
  • Middle Aged
  • Non-alcoholic Fatty Liver Disease* / diagnostic imaging
  • Non-alcoholic Fatty Liver Disease* / pathology
  • Prospective Studies