Introduction: Optimal intraoperative fluid management guided by central venous pressure (CVP), a traditional intravascular volume status indicator, has improved transplanted graft function during kidney transplantation (KT). Pulse pressure variation (PPV) and stroke volume variation (SVV) - dynamic preload indexes - are robust predictors of fluid responsiveness. This study aimed to compare the accuracy of PPV and CVP against SVV in predicting fluid responsiveness in terms of cost-effectiveness after a standardised empiric volume challenge in KT patients.
Methods: 36 patients undergoing living-donor KT were analysed. PPV, SVV, CVP and cardiac index (CI) were measured before and after fluid loading with a hydroxyethyl starch solution (7 mL/kg of ideal body weight). Patients were classified as responders (n = 12) or non-responders (n = 24) to fluid loading when CI increases were ≥10% or <10%, respectively. The ability of PPV, SVV and CVP to predict fluid responsiveness was assessed using receiver operating characteristic (ROC) curves.
Results: SVV and CVP measured before fluid loading were correlated with changes in CI caused by fluid expansion (ρ = 0.33, P = 0.049 and ρ = -0.37, P = 0.026) in contrast to PPV (ρ = 0.14, P = 0.429). The ROC analysis showed that SVV and CVP predicted response to volume loading (area under the ROC curve = 0.781 and 0.727, respectively; P < 0.05).
Conclusion: Under the conditions of our study, SVV and CVP exhibited similar performance in predicting fluid responsiveness and could inform fluid management during KT as compared with PPV.
Keywords: Central venous pressure; fluid therapy; kidney transplantation; pulse pressure variation; stroke volume variation.