Cross-Axis projection error in optically pumped magnetometers and its implication for magnetoencephalography systems
- PMID: 34915157
- PMCID: PMC8929686
- DOI: 10.1016/j.neuroimage.2021.118818
Cross-Axis projection error in optically pumped magnetometers and its implication for magnetoencephalography systems
Abstract
Optically pumped magnetometers (OPMs) developed for magnetoencephalography (MEG) typically operate in the spin-exchange-relaxation-free (SERF) regime and measure a magnetic field component perpendicular to the propagation axis of the optical-pumping photons. The most common type of OPM for MEG employs alkali atoms, e.g. 87Rb, as the sensing element and one or more lasers for preparation and interrogation of the magnetically sensitive states of the alkali atoms ensemble. The sensitivity of the OPM can be greatly enhanced by operating it in the SERF regime, where the alkali atoms' spin exchange rate is much faster than the Larmor precession frequency. The SERF regime accommodates remnant static magnetic fields up to ±5 nT. However, in the presented work, through simulation and experiment, we demonstrate that multi-axis magnetic signals in the presence of small remnant static magnetic fields, not violating the SERF criteria, can introduce significant error terms in OPM's output signal. We call these deterministic errors cross-axis projection errors (CAPE), where magnetic field components of the MEG signal perpendicular to the nominal sensing axis contribute to the OPM signal giving rise to substantial amplitude and phase errors. Furthermore, through simulation, we have discovered that CAPE can degrade localization and calibration accuracy of OPM-based magnetoencephalography (OPM-MEG) systems.
Keywords: CAPE; Cross-axis projection error; MEG; Magnetoencephalography; OPM; OPM-MEG; Source localization.
Copyright © 2021. Published by Elsevier Inc.
Conflict of interest statement
Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Figures
Similar articles
-
Cross-Axis Dynamic Field Compensation of Optically Pumped Magnetometer Arrays for MEG.Neuroimage. 2022 Nov 15;262:119559. doi: 10.1016/j.neuroimage.2022.119559. Epub 2022 Aug 13. Neuroimage. 2022. PMID: 35970471 Free PMC article.
-
A 20-channel magnetoencephalography system based on optically pumped magnetometers.Phys Med Biol. 2017 Nov 10;62(23):8909-8923. doi: 10.1088/1361-6560/aa93d1. Phys Med Biol. 2017. PMID: 29035875 Free PMC article.
-
Compensation System for Biomagnetic Measurements with Optically Pumped Magnetometers inside a Magnetically Shielded Room.Sensors (Basel). 2020 Aug 14;20(16):4563. doi: 10.3390/s20164563. Sensors (Basel). 2020. PMID: 32823964 Free PMC article.
-
Optically pumped magnetometers: From quantum origins to multi-channel magnetoencephalography.Neuroimage. 2019 Oct 1;199:598-608. doi: 10.1016/j.neuroimage.2019.05.063. Epub 2019 May 26. Neuroimage. 2019. PMID: 31141737 Free PMC article. Review.
-
Applications of OPM-MEG for translational neuroscience: a perspective.Transl Psychiatry. 2024 Aug 24;14(1):341. doi: 10.1038/s41398-024-03047-y. Transl Psychiatry. 2024. PMID: 39181883 Free PMC article. Review.
Cited by
-
Four-channel optically pumped magnetometer for a magnetoencephalography sensor array.Opt Express. 2024 May 6;32(10):18334-18351. doi: 10.1364/OE.517961. Opt Express. 2024. PMID: 38858992
-
Quantum enabled functional neuroimaging: the why and how of magnetoencephalography using optically pumped magnetometers.Contemp Phys. 2022;63(3):161-179. doi: 10.1080/00107514.2023.2182950. Epub 2023 Mar 30. Contemp Phys. 2022. PMID: 38463461 Free PMC article.
-
Combining OPM and lesion mapping data for epilepsy surgery planning: a simulation study.Sci Rep. 2024 Feb 4;14(1):2882. doi: 10.1038/s41598-024-51857-3. Sci Rep. 2024. PMID: 38311614 Free PMC article.
-
Cross-Axis Dynamic Field Compensation of Optically Pumped Magnetometer Arrays for MEG.Neuroimage. 2022 Nov 15;262:119559. doi: 10.1016/j.neuroimage.2022.119559. Epub 2022 Aug 13. Neuroimage. 2022. PMID: 35970471 Free PMC article.
-
Feasibility of magnetomyography with optically pumped magnetometers in a mobile magnetic shield.Sci Rep. 2024 Aug 16;14(1):18960. doi: 10.1038/s41598-024-69829-y. Sci Rep. 2024. PMID: 39147875 Free PMC article.
References
-
- Cohen-Tannoudji C, Dupont-Roc J, Haroche S, Laloë FJRPA, 1970. Diverses résonances de croisement de niveaux sur des atomes pompés optiquement en champ nul. I. Théorie 5 (1), 95–101.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Research Materials
Miscellaneous
