Laterally Placed Expandable Interbody Spacers With and Without Adjustable Lordosis Improve Radiographic and Clinical Outcomes: A Two-Year Follow-Up Study

Cureus. 2021 Dec 9;13(12):e20302. doi: 10.7759/cureus.20302. eCollection 2021 Dec.

Abstract

Introduction Interbody spacers are necessary for achieving disc height restoration when surgical intervention is used for the treatment of severe degenerative disc disease. Minimally invasive lateral lumbar interbody fusion (MIS LLIF) is a popular surgical approach that historically uses large static interbody spacers through a lateral approach. However, static spacers have been associated with iatrogenic distraction and excessive impaction forces, which may increase the risk of subsidence and loss of lordosis, compromising stability. Expandable interbody spacers with or without adjustable lordosis may help address these concerns by maximizing segmental lordosis and aiding in sagittal balance correction. This study describes the clinical and radiographic outcomes of patients treated with expandable interbody spacers with or without adjustable lordosis, for MIS LLIF. Materials and methods This is retrospective, single-surgeon Institutional Review Board-exempt chart review was of 103 consecutive patients who had undergone MIS LLIF at one to two contiguous level(s) utilizing expandable interbody spacers with or without adjustable lordosis (66/103 patients had adjustable lordosis spacers). Collection of clinical and radiographic functional outcomes occurred at preoperative and postoperative time points through 24 months. Results One-hundred and three consecutive patients were evaluated-average age, 58.2 ± 12.1 years; 42.1% (45/107) were female. There were 78.6% (81/103) one-level cases and 21.4% (22/103) two-level cases for a total of 125 levels; 44.8% (56/125) were performed at L4-5 and 34.4% (43/125) at L3-4. The average estimated blood loss was 24.6 ± 12.3cc. Mean operative time was 61.0 ± 19.1 min, and mean fluoroscopic time was 28.2 ± 14.6 sec. Visual Analog Scale (VAS) back and leg pain scores decreased significantly by an average of 7.1 ± 1.0 points at 24 months (p<0.001). Oswestry Disability Index (ODI) scores significantly decreased by a mean of 67.4 ± 8.9 points at 24 months (p<0.001). Lumbar lordosis significantly improved by a mean of 3.1 ± 8.8° at 24 months (p=0.001). Anterior, middle, and posterior disc height significantly increased at 24 months by averages of 4.7 ± 3.1, 4.0 ± 3.0, and 2.1 ± 2.2mm, respectively (p<0.001). Neuroforaminal height had significantly increased at 24 months by a mean of 3.0 ± 3.6mm (p<0.001). Segmental lordosis significantly improved by 3.7 ± 2.9° at 24 months (p<0.001). There were 51 patients with abnormal preoperative Pelvic Incidence-Lumbar Lordosis (PI-LL) measurements that significantly improved by 9.1 ± 4.9° (p<0.001) and 52 patients with normal preoperative PI-LL measurements that improved by 0.2 ± 4.6° (p=0.748) at 24 months. One-hundred percent fusion occurred at all levels, and no findings of radiolucency were observed. One case of subsidence (1/125, 0.8%) was reported at 24 months. No implanted-related complications were reported, with 0% pseudoarthrosis and no secondary surgery required at the operative levels. Conclusion Indirect decompression and sagittal correction were achieved and maintained through a 24-month follow-up. Functional clinical outcomes significantly improved based on decreased VAS pain and ODI scores at 24 months. This study resulted in positive clinical and radiographic outcomes for patients who underwent MIS LLIF with expandable interbody spacers with or without adjustable lordosis.

Keywords: adjustable lordosis; degenerative disc disease; expandable interbody spacers; mis llif; sagittal correction.