Serum Ferritin Threshold for Iron Deficiency Screening in One-Year-Old Children

J Pediatr. 2022 Jun:245:217-221. doi: 10.1016/j.jpeds.2022.01.050. Epub 2022 Jan 31.

Abstract

The American Academy of Pediatrics recommends universal hemoglobin screening for iron deficiency anemia using hemoglobin <110 g/L at the 1-year-old well child visit. Our retrospective study suggests the need for combined hemoglobin and serum ferritin iron deficiency screening and raising the diagnostic serum ferritin threshold to 24-25 μg/L.

Keywords: anemia; hemoglobin; restricted cubic spline regression.

Publication types

  • Case Reports
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Anemia, Iron-Deficiency* / diagnosis
  • Child
  • Ferritins
  • Hemoglobins / analysis
  • Humans
  • Infant
  • Iron Deficiencies*
  • Retrospective Studies

Substances

  • Hemoglobins
  • Ferritins