Magnetic Field Measurements of Portable Electronic Devices: The Risk Inside Pockets for Patients With Cardiovascular Implantable Devices
- PMID: 35227069
- DOI: 10.1161/CIRCEP.121.010646
Magnetic Field Measurements of Portable Electronic Devices: The Risk Inside Pockets for Patients With Cardiovascular Implantable Devices
Keywords: defibrillators; electronic devices; magnetic fields; magnets; tachycardia.
Similar articles
-
Magnetic field interactions between current consumer electronics and cardiac implantable electronic devices.J Interv Card Electrophysiol. 2022 Oct;65(1):133-139. doi: 10.1007/s10840-022-01241-w. Epub 2022 May 10. J Interv Card Electrophysiol. 2022. PMID: 35538270
-
Magnetic field-induced interactions between phones containing magnets and cardiovascular implantable electronic devices: Flip it to be safe?Heart Rhythm. 2022 Mar;19(3):372-380. doi: 10.1016/j.hrthm.2021.11.010. Epub 2021 Nov 10. Heart Rhythm. 2022. PMID: 34767986
-
To the Editor-Interference of smartphones containing magnets and cardiac implantable electronic devices-Is this common?Heart Rhythm. 2021 Jun;18(6):1042-1043. doi: 10.1016/j.hrthm.2021.02.023. Epub 2021 Mar 9. Heart Rhythm. 2021. PMID: 33706006 No abstract available.
-
Perioperative Interrogation of Medtronic Cardiovascular Implantable Electronic Devices: A Guide for Anesthesiologists.J Cardiothorac Vasc Anesth. 2020 Sep;34(9):2465-2475. doi: 10.1053/j.jvca.2019.09.012. Epub 2019 Sep 15. J Cardiothorac Vasc Anesth. 2020. PMID: 31587927 Review.
-
Perioperative Interrogation of St. Jude Cardiovascular Implantable Electronic Devices: A Guide for Anesthesiologists.J Cardiothorac Vasc Anesth. 2018 Apr;32(2):982-1000. doi: 10.1053/j.jvca.2017.11.050. Epub 2017 Dec 1. J Cardiothorac Vasc Anesth. 2018. PMID: 29291968 Review.
Cited by
-
High-Fidelity 3D Stray Magnetic Field Mapping of Smartphones to Address Safety Considerations with Active Implantable Electronic Medical Devices.Sensors (Basel). 2023 Jan 20;23(3):1209. doi: 10.3390/s23031209. Sensors (Basel). 2023. PMID: 36772249 Free PMC article.
-
Cardiac Implantable Electronic Devices and Consumer Electronic Devices: The Proof Is in the Front Pocket.J Innov Card Rhythm Manag. 2022 Jul 15;13(7):5073-5076. doi: 10.19102/icrm.2022.130706. eCollection 2022 Jul. J Innov Card Rhythm Manag. 2022. PMID: 35949651 Free PMC article. No abstract available.
-
Magnetic interactions between CIEDs and consumer devices: a little distance goes a long way.J Interv Card Electrophysiol. 2022 Oct;65(1):261-262. doi: 10.1007/s10840-022-01280-3. Epub 2022 Jun 15. J Interv Card Electrophysiol. 2022. PMID: 35705733 No abstract available.
-
Magnetic field interactions between current consumer electronics and cardiac implantable electronic devices.J Interv Card Electrophysiol. 2022 Oct;65(1):133-139. doi: 10.1007/s10840-022-01241-w. Epub 2022 May 10. J Interv Card Electrophysiol. 2022. PMID: 35538270