Use of ultrasound and targeted physiotherapy to manage nerve sutures placed under joint flexion: a case series

Acta Neurochir (Wien). 2022 May;164(5):1329-1336. doi: 10.1007/s00701-022-05195-w. Epub 2022 Apr 4.

Abstract

Background: Joint flexion to diminish the gap and avoid nerve grafts fell into disuse for decades, but recently attention for using this technique was regained. We report a case series of nerve suture under joint flexion, ultrasound monitoring, and physiotherapy. Our main objective was to determine how effective this multimodality treatment is.

Methods: A retrospective review of 8 patients treated with direct repair with joint flexion was done. Depending on the affected nerve, either the knee or the elbow was flexed intraoperatively to determine if direct suturing was possible. After surgery, the limb was held immobilized. Through serial ultrasounds and a physiotherapy program, the limb was fully extended. If a nerve repair rupture was observed, the patient was re-operated and grafts were used.

Results: Of the eight nerve sutures analyzed, four sustained a nerve rupture revealed by US at an early stage, while four did not show any sign of dehiscence. In the patients in whom the nerve suture was preserved, an early and very good response was observed. Ultrasound was 100% accurate at identifying nerve suture preservation. Early detection of nerve failure permitted early re-do surgery using grafts without flexion, ultimately determining good final results.

Conclusions: We observed a high rate of dehiscence in our group of patients treated with direct repair and joint flexion. We believe this was due to an incorrect use of the immobilization device, excessive movement, or a broken device. In opposition to this, we observed that applying direct nerve sutures and joint flexion offers unusually good and fast results. If this technique is employed, it is mandatory to closely monitor suture status with US, together with physiotherapy providing progressive, US-guided extension of the flexed joint. If nerve rupture occurs, the close monitoring dictated by this protocol should ensure the timely application of a successful graft repair.

Keywords: Immobilization; Joint flexion; Nerve injury; Nerve suture; Ultrasound.

MeSH terms

  • Humans
  • Physical Therapy Modalities
  • Plastic Surgery Procedures*
  • Range of Motion, Articular
  • Rupture / surgery
  • Sutures*