Abstract
Background Magnetoencephalography (MEG) is an established method used to detect and localize focal interictal epileptiform discharges (IEDs). Current MEG systems house hundreds of cryogenic sensors in a rigid, one-size-fits-all helmet, which results in several limitations, particularly in children. Purpose To determine if on-scalp MEG based on optically pumped magnetometers (OPMs) alleviates the main limitations of cryogenic MEG. Materials and Methods In this prospective single-center study conducted in a tertiary university teaching hospital, participants underwent cryogenic (102 magnetometers, 204 planar gradiometers) and on-scalp (32 OPMs) MEG. The two modalities for the detection and localization of IEDs were compared. The t test was used to compare IED amplitude and signal-to-noise ratio (SNR). Distributed source modeling was performed on OPM-based and cryogenic MEG data. Results Five children (median age, 9.4 years [range, 5-11 years]; four girls) with self-limited idiopathic (n = 3) or refractory (n = 2) focal epilepsy were included. IEDs were identified in all five children with comparable sensor topographies for both MEG devices. IED amplitudes were 2.3 (7.2 of 3.1) to 4.6 (3.2 of 0.7) times higher (P < .001) with on-scalp MEG, and the SNR was 27% (16.7 of 13.2) to 60% (12.8 of 8.0) higher (P value range: .001-.009) with on-scalp MEG in all but one participant (P = .93), whose head movements created pronounced motion artifacts. The neural source of averaged IEDs was located at approximately 5 mm (n = 3) or higher (8.3 mm, n = 1; 15.6 mm, n = 1) between on-scalp and cryogenic MEG. Conclusion Despite the limited number of sensors and scalp coverage, on-scalp magnetoencephalography (MEG) based on optically pumped magnetometers helped detect interictal epileptiform discharges in school-aged children with epilepsy with a higher amplitude, higher signal-to-noise ratio, and similar localization value compared with conventional cryogenic MEG. Online supplemental material is available for this article. © RSNA, 2022 See also the editorial by Widjaja in this issue.
Comment in
-
Wearable Magnetoencephalography: Reality or Science Fiction?Radiology. 2022 Aug;304(2):435-436. doi: 10.1148/radiol.220609. Epub 2022 May 3. Radiology. 2022. PMID: 35503021 No abstract available.
Similar articles
-
Non-invasive measurements of ictal and interictal epileptiform activity using optically pumped magnetometers.Sci Rep. 2023 Mar 21;13(1):4623. doi: 10.1038/s41598-023-31111-y. Sci Rep. 2023. PMID: 36944674 Free PMC article.
-
Tri-axial rubidium and helium optically pumped magnetometers for on-scalp magnetoencephalography recording of interictal epileptiform discharges: a case study.Front Neurosci. 2023 Nov 27;17:1284262. doi: 10.3389/fnins.2023.1284262. eCollection 2023. Front Neurosci. 2023. PMID: 38089970 Free PMC article.
-
From cryogenic to on-scalp magnetoencephalography for the evaluation of paediatric epilepsy.Dev Med Child Neurol. 2024 Mar;66(3):298-306. doi: 10.1111/dmcn.15689. Epub 2023 Jul 8. Dev Med Child Neurol. 2024. PMID: 37421175 Review.
-
Interictal and ictal source localization for epilepsy surgery using high-density EEG with MEG: a prospective long-term study.Brain. 2019 Apr 1;142(4):932-951. doi: 10.1093/brain/awz015. Brain. 2019. PMID: 30805596 Free PMC article.
-
Redefining the role of Magnetoencephalography in refractory epilepsy.Seizure. 2020 Dec;83:70-75. doi: 10.1016/j.seizure.2020.10.010. Epub 2020 Oct 17. Seizure. 2020. PMID: 33096459 Review.
Cited by
-
An Iterative Implementation of the Signal Space Separation Method for Magnetoencephalography Systems with Low Channel Counts.Sensors (Basel). 2023 Jul 20;23(14):6537. doi: 10.3390/s23146537. Sensors (Basel). 2023. PMID: 37514831 Free PMC article.
-
Naturalistic Hyperscanning with Wearable Magnetoencephalography.Sensors (Basel). 2023 Jun 9;23(12):5454. doi: 10.3390/s23125454. Sensors (Basel). 2023. PMID: 37420622 Free PMC article.
-
Helium Optically Pumped Magnetometers Can Detect Epileptic Abnormalities as Well as SQUIDs as Shown by Intracerebral Recordings.eNeuro. 2023 Dec 22;10(12):ENEURO.0222-23.2023. doi: 10.1523/ENEURO.0222-23.2023. Print 2023 Dec. eNeuro. 2023. PMID: 37932045 Free PMC article.
-
Improved Biomagnetic Signal-To-Noise Ratio and Source Localization Using Optically Pumped Magnetometers with Synthetic Gradiometers.Brain Sci. 2023 Apr 15;13(4):663. doi: 10.3390/brainsci13040663. Brain Sci. 2023. PMID: 37190628 Free PMC article.
-
A novel, robust, and portable platform for magnetoencephalography using optically-pumped magnetometers.Imaging Neurosci (Camb). 2024 Sep 25;2:1-22. doi: 10.1162/imag_a_00283. eCollection 2024 Sep 1. Imaging Neurosci (Camb). 2024. PMID: 39502465 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical