Influence of flow rate and different size of suction cannulas on splatter contamination in dentistry: results of an exploratory study with a high-volume evacuation system

Clin Oral Investig. 2022 Sep;26(9):5687-5696. doi: 10.1007/s00784-022-04525-7. Epub 2022 May 10.

Abstract

Objectives: SOPs recommend high-volume evacuation (HVE) for aerosol-generating procedures (AGPs) in dentistry. Therefore, in the exploratory study, the area of splatter contamination (SCON in %) generated by high-speed tooth preparation (HSP) and air-polishing (APD) was measured when different suction cannulas of 6 mm diameter (saliva ejector (SAE)), 11 mm (HC11), or 16 mm (HC16) were utilized versus no-suction (NS).

Materials and methods: Eighty tests were performed in a closed darkened room to measure SCON (1m circular around the manikin head (3.14 m2) via plan metrically assessment through fluorescence technique. HSP (handpiece, turbine (Kavo, Germany)) or APD (LM-ProPowerTM (Finland), Airflow®-Prophylaxis-Master (Switzerland)) for 6 min plus 5 s post-treatment were performed either without suction or with low-flow (150 l/min for SAE) or high-flow rate (250 l/min/350 l/min for HC11/HC16) suction. All tests were two-tailed (p≤0.05, Bonferroni corrected for multi-testing).

Results: Irrespective the AGP, SCON was higher for NS (median [25th; 75th percentiles]: 3.4% [2.6; 5.4]) versus high-flow suction (1.9% [1.5; 2.5]) (p=0.002). Low-flow suction (3.5% [2.6; 4.3]) versus NS resulted in slightly lower but not statistically significantly lower SCON (p=1.000) and was less effective than high-flow suction (p=0.003). Lowest contamination values were found with HC16 (1.9% [1.5; 2.5]; p≤0.002), whereat no significant differences were found for HC11 (2.4% [1.7; 3.1]) compared to SAE (p=0.385) or NS (p=0.316).

Conclusions: Within study's limitations, the lowest splatter contamination values resulted when HC16 were utilized by a high-flow rate of ≥250 l/min.

Clinical relevance: It is strongly recommended to utilize an HVE with suction cannulas of 16mm diameter for a high-flow rate during all AGPs and afterwards also to disinfect all surface of patients or operators contacted.

Keywords: Air-polishing; Experimental setup; Splatter contamination; SARS-CoV2; Suction system; Tooth preparation.

MeSH terms

  • Aerosols
  • Cannula*
  • Dentistry*
  • Finland
  • Humans
  • Suction* / instrumentation
  • Tooth Preparation*

Substances

  • Aerosols