Cup placement in primary total hip arthroplasty: how to get it right without navigation or robotics

EFORT Open Rev. 2022 May 31;7(6):365-374. doi: 10.1530/EOR-22-0025.

Abstract

Acetabular component orientation and position are important factors in the short- and long-term outcomes of total hip arthroplasty. Different definitions of inclination and anteversion are used in the orthopaedic literature and surgeons should be aware of these differences and understand their relationships. There is no universal safe zone. Preoperative planning should be used to determine the optimum position and orientation of the cup and assess spinopelvic characteristics to adjust cup orientation accordingly. A peripheral reaming technique leads to a more accurate restoration of the centre of rotation with less variability compared with a standard reaming technique. Several intraoperative landmarks can be used to control the version of the cup, the most commonly used and studied is the transverse acetabular ligament. The use of an inclinometer reduces the variability associated with the use of freehand or mechanical alignment guides.

Keywords: cup; orientation; total hip.

Publication types

  • Review