Longitudinal changes in fetal head biometry and fetoplacental circulation in fetuses with congenital heart defects

Acta Obstet Gynecol Scand. 2022 Sep;101(9):987-995. doi: 10.1111/aogs.14401. Epub 2022 Jun 20.

Abstract

Introduction: Objectives were to analyze changes in fetal cephalic biometry and fetoplacental circulation throughout pregnancy in fetuses with congenital heart defects.

Material and methods: Prospective study conducted on three university tertiary referral hospitals. Fetuses with the diagnosis of isolated congenital heart defects attending between 2014 and 2018 were included. Congenital heart defects were divided into two groups according to the oxygen supply to the central nervous system: group I (expected low placental blood content and low oxygen delivery to the brain) and group II (expected intermediate and high placental blood content). Fetal biometry and Doppler parameters were collected between 25-30 weeks of gestation and 34-40 weeks of gestation and transformed into Z scores. The results were compared with healthy controls. Finally, general linear modeling was performed to analyze repeated measurements.

Results: In all, 71 fetuses met the inclusion criteria. Fetuses with congenital heart defects had significantly smaller head (biparietal diameter [p < 0.001], head circumference [p = 0.001]) and abdominal circumference (p < 0.001), and lower estimated fetal weight (p < 0.001) than controls. When analyzing according to congenital heart defects type, head size was significantly smaller in group I compared with group II (p = 0.04). Regarding Doppler parameters, fetuses with congenital heart defects showed higher umbilical artery pulsatility index (p < 0.001) and lower cerebroplacental ratio (p = 0.044) than controls. In group I, umbilical artery pulsatility index was above the 95th centile in 15.4% of fetuses compared with 6.7% in group II and 1.9% in controls (p < 0.001); moreover, middle cerebral artery pulsatility index was below the 5th centile in 5.4% of group I fetuses compared with 0% in group II and 1.2% in controls (p = 0.011). General linear model for two measurements showed significant longitudinal changes in biometric parameters. Growth rate of fetal head through pregnancy (head circumference Z score) was lower in fetuses with congenital heart defects compared with controls (p = 0.043). In group I, the head circumference Z score longitudinal decrease was significantly higher than in group II (p < 0.001).

Conclusions: Fetuses with congenital heart defects are at risk of smaller head size and Doppler changes. Growth rate of fetal head throughout pregnancy is also affected. These findings are mainly associated with cardiac defects with expected low oxygen supply to the central nervous system.

Keywords: Doppler flow; congenital heart disease; fetal biometry; head size; longitudinal changes.

MeSH terms

  • Biometry / methods
  • Female
  • Fetal Growth Retardation
  • Fetus
  • Gestational Age
  • Heart Defects, Congenital* / complications
  • Heart Defects, Congenital* / diagnostic imaging
  • Humans
  • Oxygen
  • Placenta / blood supply
  • Placental Circulation*
  • Pregnancy
  • Prospective Studies
  • Ultrasonography, Prenatal
  • Umbilical Arteries / diagnostic imaging
  • Umbilical Arteries / physiology

Substances

  • Oxygen