Point-of-Care Brain MRI: Preliminary Results from a Single-Center Retrospective Study

Radiology. 2022 Dec;305(3):666-671. doi: 10.1148/radiol.211721. Epub 2022 Aug 2.

Abstract

Background Point-of-care (POC) MRI is a bedside imaging technology with fewer than five units in clinical use in the United States and a paucity of scientific studies on clinical applications. Purpose To evaluate the clinical and operational impacts of deploying POC MRI in emergency department (ED) and intensive care unit (ICU) patient settings for bedside neuroimaging, including the turnaround time. Materials and Methods In this preliminary retrospective study, all patients in the ED and ICU at a single academic medical center who underwent noncontrast brain MRI from January 2021 to June 2021 were investigated to determine the number of patients who underwent bedside POC MRI. Turnaround time, examination limitations, relevant findings, and potential CT and fixed MRI findings were recorded for patients who underwent POC MRI. Descriptive statistics were used to describe clinical variables. The Mann-Whitney U test was used to compare the turnaround time between POC MRI and fixed MRI examinations. Results Of 638 noncontrast brain MRI examinations, 36 POC MRI examinations were performed in 35 patients (median age, 66 years [IQR, 57-77 years]; 21 women), with one patient undergoing two POC MRI examinations. Of the 36 POC MRI examinations, 13 (36%) occurred in the ED and 23 (64%) in the ICU. There were 12 of 36 (33%) POC MRI examinations interpreted as negative, 14 of 36 (39%) with clinically significant imaging findings, and 10 of 36 (28%) deemed nondiagnostic for reasons such as patient motion. Of 23 diagnostic POC MRI examinations with comparison CT available, three (13%) demonstrated acute infarctions not apparent on CT scans. Of seven diagnostic POC MRI examinations with subsequent fixed MRI examinations, two (29%) demonstrated missed versus interval subcentimeter infarctions, while the remaining demonstrated no change. The median turnaround time of POC MRI was 3.4 hours in the ED and 5.3 hours in the ICU. Conclusion Point-of-care (POC) MRI was performed rapidly in the emergency department and intensive care unit. A few POC MRI examinations demonstrated acute infarctions not apparent at standard-of-care CT examinations. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Anzai and Moy in this issue.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Brain / diagnostic imaging
  • Emergency Service, Hospital*
  • Female
  • Humans
  • Infarction
  • Magnetic Resonance Imaging
  • Neuroimaging
  • Point-of-Care Systems*
  • Retrospective Studies