Effectiveness of Standard vs Enhanced Self-measurement of Blood Pressure Paired With a Connected Smartphone Application: A Randomized Clinical Trial

JAMA Intern Med. 2022 Oct 1;182(10):1025-1034. doi: 10.1001/jamainternmed.2022.3355.

Abstract

Importance: Self-measured blood pressure (SMBP) with commercially available connected smartphone applications may help patients effectively use SMBP measurements.

Objective: To determine if enhanced SMBP paired with a connected smartphone application was superior to standard SMBP for blood pressure (BP) reduction or patient satisfaction.

Design, setting, and participants: This randomized clinical trial was conducted among 23 health systems participating in PCORnet, the National Patient-Centered Clinical Research Network, and included patients who reported having uncontrolled BP at their last clinic visit, a desire to lower their BP, and a smartphone. Enrollment and randomization occurred from August 3, 2019, to December 31, 2020, which was followed by 6 months of follow-up for each patient. Analysis commenced shortly thereafter.

Interventions: Eligible participants were randomly assigned to enhanced SMBP using a device that paired with a connected smartphone application (enhanced) or a standard device (standard). Participants received their device in the mail, along with web-based educational materials and phone-based support as needed. No clinician engagement was undertaken, and the study provided no special mechanisms for delivering measurements to clinicians for use in BP management.

Main outcomes and measures: Reduction in systolic BP, defined as the difference between clinic BP at baseline and the most recent clinic BP extracted from electronic health records at 6 months.

Results: Enrolled participants (1051 enhanced [50.0%] vs 1050 standard [50.0%]; 1191 women [56.7%]) were mostly middle-aged or older (mean [SD] age, 58 [13] years), nearly a third were Black or Hispanic (645 [31%]), and most were relatively comfortable using technology (mean [SD], 4.1 [1.1] of 5). The mean (SD) change in systolic BP from baseline to 6 months was -10.8 (18) mm Hg vs -10.6 (18) mm Hg (enhanced vs standard: adjusted difference, -0.19 mm Hg; 95% CI, -1.83 to 1.44; P = .81). Secondary outcomes were mostly null, except for documented attainment of BP control to lower than 140/<90 mm Hg, which occurred in 32% enhanced vs 29% standard groups (odds ratio, 1.15; 95% CI, 1.01-1.34). Most participants were very likely to recommend their SMBP device to a friend (70% vs 69%).

Conclusions and relevance: This randomized clinical trial found that enhanced SMBP paired with a smartphone application is not superior to standard SMBP for BP reduction or patient satisfaction.

Trial registration: ClinicalTrials.gov Identifier: NCT03796689.

Publication types

  • Randomized Controlled Trial

MeSH terms

  • Blood Pressure
  • Blood Pressure Monitoring, Ambulatory
  • Female
  • Humans
  • Hypertension* / diagnosis
  • Middle Aged
  • Mobile Applications*
  • Smartphone

Associated data

  • ClinicalTrials.gov/NCT03796689