Outcomes 12 Months After Temperature-Controlled Radiofrequency Device Treatment of the Nasal Valve for Patients With Nasal Airway Obstruction

JAMA Otolaryngol Head Neck Surg. 2022 Oct 1;148(10):940-946. doi: 10.1001/jamaoto.2022.2293.

Abstract

Importance: Nasal valve collapse is a primary cause of nasal airway obstruction (NAO). Patients with NAO and nasal valve collapse experience a variety of symptoms that lower their quality of life, such as nasal congestion, headache, sleep disturbance, daytime sleepiness, and snoring.

Objective: To determine if active treatment of the nasal valve with a temperature-controlled radiofrequency (TCRF) device, previously demonstrated superior to a sham procedure at 3 months, was safe and associated with sustained improvements in symptoms of NAO through 12 months.

Design, setting, and participants: In a prospective, multicenter, single-blinded, randomized clinical trial, patients in 16 centers in the US with index procedures between August and December 2020 were assigned to TCRF device treatment of the nasal valve or a sham control procedure (no RF energy). Patients had a baseline Nasal Obstruction Symptom Evaluation (NOSE) Scale score of 55 or greater with nasal valve collapse as the primary or substantial contributor to NAO. After primary end point evaluation at 3 months, eligible patients in the sham control arm crossed over to active treatment. Data analysis was performed between April and May 2022.

Interventions: Patients were treated bilaterally with the TCRF device at 4 or fewer nonoverlapping areas on the nasal mucosa at the junction of the upper and lower lateral cartilage on the lateral nasal wall.

Main outcomes and measures: The primary end point measure was responder rate, defined as 20% or greater reduction in NOSE Scale score or 1 or greater reduction in NOSE Scale clinical severity category.

Results: A total of 108 patients received active treatment (77 as index active treatment, 31 after crossover). The mean (SD) age of patients was 48.5 (12.3) years; 66 (61.1%) were women. The combined group of patients receiving active treatment had a mean baseline NOSE Scale score of 76.3 (95% CI, 73.6-79.1). At 12 months (n = 88), the responder rate was 89.8% (95% CI, 81.7%-94.5%). The NOSE Scale score improved from baseline (mean change, -44.9 [95% CI, -52.1 to -37.7]). No device/procedure-related serious adverse events were reported.

Conclusions and relevance: In this follow-up of a cohort from a randomized clinical trial, the minimally invasive TCRF device, previously demonstrated to be superior to a sham procedure, was safe and associated with improvement in symptoms of NAO through 12 months postprocedure.

Trial registration: ClinicalTrials.gov Identifier: NCT04549545.

Publication types

  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Female
  • Humans
  • Male
  • Middle Aged
  • Nasal Obstruction* / complications
  • Nasal Obstruction* / surgery
  • Prospective Studies
  • Quality of Life
  • Temperature
  • Treatment Outcome

Associated data

  • ClinicalTrials.gov/NCT04549545