TREATMENT OF PERSISTENT MACULAR HOLES WITH HEAVY SILICONE OIL

Retina. 2022 Dec 1;42(12):2258-2266. doi: 10.1097/IAE.0000000000003620.

Abstract

Background/purpose: To determine anatomical success and best-corrected visual acuity after secondary surgery with heavy silicone oil tamponade in patients with persistent full-thickness macular holes.

Methods: In this retrospective study, 63 eyes with persistent full-thickness macular holes after primary pars plana vitrectomy and internal limiting membrane peeling underwent secondary surgery with heavy silicone oil tamponade. Macular spectral domain optical coherence tomography and best-corrected visual acuity measurements were performed during the follow-up.

Results: Fifty of 63 eyes (79.4%) achieved anatomical success. In eyes achieving anatomical success, best-corrected visual acuity before primary vitreoretinal surgery was significantly better (0.77 [∼20/125 Snellen] ± 0.24 [1.3-0.3] logarithm of the minimum angle of resolution) compared with eyes not achieving anatomical success (0.88 [∼20/160 Snellen] ± 0.17 [1.1-0.6] logarithm of the minimum angle of resolution, P = 0.044). Minimum linear diameter of full-thickness macular holes was significantly smaller in eyes achieving anatomical success, both before primary (403.4 ± 128.7 [199.0-707.0] µ m vs. 568.1 ± 209.1 [307.0-953.0] µ m, P = 0.009) and secondary surgery (464.1 ± 215.0 [178.0-1,521.0] µ m vs. 663.3 ± 228.5 [451.0-1,301.0] µ m, P = 0.010). Patients remaining phakic during all three surgeries did not benefit from best-corrected visual acuity improvement, although anatomical success was achieved.

Conclusion: Heavy silicone oil tamponade in secondary surgery for persistent full-thickness macular holes is a safe and efficient surgical method. Best-corrected visual acuity and minimum linear diameter before surgery may be indicators for anatomical success.

MeSH terms

  • Basement Membrane / surgery
  • Humans
  • Retina
  • Retinal Perforations* / diagnosis
  • Retinal Perforations* / surgery
  • Retrospective Studies
  • Silicone Oils
  • Tomography, Optical Coherence
  • Vitrectomy / methods

Substances

  • densiron
  • Silicone Oils