Introduction: Despite progressive improvements in technical skills and instruments that have facilitated surgeons performing intracorporeal gastro-jejunal and jejuno-jejunal anastomoses, one of the big challenging tasks is handsewn knot tying. We analysed the better way to fashion a handsewn intracorporeal enterotomy closure after a stapled anastomosis.
Methods: All 579 consecutive patients from January 2009 to December 2019 who underwent minimally invasive partial gastrectomy for gastric cancer were retrospectively analysed. Different ways to fashion intracorporeal anastomoses were investigated: robotic versus laparoscopic approach; laparoscopic high definition versus three-dimensional versus 4K technology; single-layer versus double-layer enterotomies. Double-layer enterotomies were analysed layer by layer, comparing running versus interrupted suture; the presence versus absence of deep corner suture; and type of suture thread.
Results: Significantly lower rates of bleeding (p = 0.011) and leakage (p = 0.048) from gastro-jejunal anastomosis were recorded in the double-layer group. Barbed suture thread was significantly associated with reduced intraluminal bleeding and leakage rates both in the first (p = 0.042 and p = 0.010) and second layer (p = 0.002 and p = 0.029).
Conclusions: Double-layer sutures using barbed suture thread both in first and second layer to fashion enterotomy closure result in lower intraluminal bleeding and anastomotic leak rates.
Keywords: Barbed suture; Double layer; Enterotomy closure; Intracorporeal gastrectomy.
© 2022 S. Karger AG, Basel.