Inadvertent placement of an esophagostomy tube into the mediastinum of a cat

Can Vet J. 2022 Nov;63(11):1124-1128.

Abstract

An 8-year-old neutered male Siberian forest cat was presented for respiratory distress. Endoscopy, exploratory surgery of the neck, and sternotomy confirmed initial placement of the esophagostomy tube (e-tube) into the mediastinum. The patient recovered from surgery, developed laryngeal paralysis, and then arrested and died within 48 h after surgery. Key clinical message: To the authors' knowledge, there are no other case reports documenting inadvertent placement of an e-tube into the mediastinum of a cat. This case report highlights the complications that can be associated with incorrect placement of an e-tube.

Placement par inadvertance d’un tube d’oesophagostomie dans le médiastin d’un chat. Un chat des Forêts sibériennes mâle castré âgé de 8 ans a été présenté pour détresse respiratoire. L’endoscopie, la chirurgie exploratoire du cou et la sternotomie ont confirmé le placement initial du tube d’oesophagostomie (e-tube) dans le médiastin. Le patient s’est remis de la chirurgie, a développé une paralysie laryngée, puis a fait un arrêt cardiaque et est décédé dans les 48 heures suivant la chirurgie.Message clinique clé:À la connaissance des auteurs, il n’y a pas d’autres rapports de cas documentant le placement par inadvertance d’un e-tube dans le médiastin d’un chat. Ce rapport de cas met en évidence les complications qui peuvent être associées au placement incorrect d’un e-tube.(Traduit par Dr Serge Messier).

Publication types

  • Case Reports

MeSH terms

  • Animals
  • Enteral Nutrition / veterinary
  • Esophagostomy* / veterinary
  • Male
  • Mediastinum*