The OptiSafe (OS) test is shelf-stable, macromolecular eye irritation test that does not include any animal ingredient or component ("vegan"). The purpose of this study was to evaluate the test's accuracy for an expanded application domain for both the original and recently updated OS method. This study involved the testing of additional ocular corrosives and previously excluded foaming agents ("surfactants") using both the original and updated OS methods and then combining these data with prior validation data for a total of 147 chemicals. Predictivity was evaluated by a statistical comparison of the OptiSafe predictions with historical in vivo "Draize" rabbit eye data for the same chemicals (from public databases). We report that for the detection of chemicals not requiring classification for eye irritation [Globally Harmonized System of Classification and Labeling of Chemicals (GHS) No Category], the accuracy, specificity, and sensitivity were 92.8%, 79.6%, and 100.0%, respectively, for the updated method; for the detection of chemicals inducing extreme eye damage/corrosion (GHS Category 1), the accuracy, specificity, and sensitivity were 79.4%, 71.8%, and 91.7%, respectively, for the updated method. Results indicate that both the original and updated methods have a high accuracy for the expanded application domain that included ocular corrosives and surfactants.
Keywords: Application domain; Nonanimal eye irritation test; Ocular irritation; OptiSafe; Validation.
Copyright © 2022 The Author(s). Published by Elsevier Ltd.. All rights reserved.