Short- and Mid-Term Outcomes of Complex and High-Risk Versus Standard Percutaneous Coronary Interventions in Patients Undergoing Transcatheter Aortic Valve Replacement

J Invasive Cardiol. 2023 Feb;35(2):E92-E98. Epub 2022 Dec 15.

Abstract

The prevalence of coronary artery disease (CAD) in patients undergoing TAVR varies and is associated with increased morbidity and mortality. We evaluated the outcomes of complex and high-risk percutaneous coronary interventions (CHIP-PCIs) and TAVR compared with standard PCI and TAVR. Between January 2014 and March 2021, a total of 276 consecutive patients with severe aortic stenosis (AS) who underwent TAVR and PCI at 3 centers within Northwell Health were retrospectively reviewed. CHIP-PCI was defined as PCI with one of the following: left ventricular ejection fraction (LVEF) <30%; left main coronary artery (LMCA)/chronic total occlusion (CTO) intervention; atherectomy; or need for left ventricular (LV) support. One hundred twenty- seven patients (46%) had CHIP-PCI prior to TAVR and 149 patients (54%) had standard PCI. Thirteen percent of CHIP-PCI and 22% of standard PCI cases were done concomitantly with TAVR. CHIP-PCI criteria were met for low EF (19%), LMCA (25%), CTO (3%), LV support (20%), and atherectomy (50%). The types of valves used were similarly divided (49% balloon expandable vs 51% self expanding. Major adverse cardiac or cerebrovascular event (MACCE) rate for CHIP-PCI/TAVR was 4.9% at 30 days vs 1.3% for standard PCI/TAVR (P=.09), driven by in-hospital stroke. At 1 year, the rates of MACCE for CHIP-PCI/TAVR remained higher than for standard PCI/TAVR, but was not statistically significant (8.7% vs 4%; P=.06), driven by revascularization. We found no differences between major and/or minor vascular complications. New York Heart Association classification at 1 month was similar (I/II 93% vs 95%; P=.87). Our study suggests that CHIP-PCI can be safely performed in patients with complex CAD and concomitant severe AS.

Keywords: CHIP-PCI; TAVR; severe aortic stenosis.

MeSH terms

  • Aortic Valve / surgery
  • Aortic Valve Stenosis* / complications
  • Aortic Valve Stenosis* / diagnosis
  • Aortic Valve Stenosis* / surgery
  • Coronary Artery Disease* / complications
  • Coronary Artery Disease* / diagnosis
  • Coronary Artery Disease* / surgery
  • Humans
  • Percutaneous Coronary Intervention* / adverse effects
  • Retrospective Studies
  • Risk Factors
  • Stroke Volume
  • Transcatheter Aortic Valve Replacement* / adverse effects
  • Treatment Outcome
  • Ventricular Function, Left