Implant-dependent behavior of tunnel widening and clavicular button migration after arthroscopic-assisted treatment of acromioclavicular joint instabilities

Eur J Orthop Surg Traumatol. 2023 Aug;33(6):2533-2540. doi: 10.1007/s00590-022-03466-x. Epub 2023 Jan 3.

Abstract

Introduction: Despite ongoing discussions for the previous few decades, there is still no consensus regarding the optimal surgical technique for acromioclavicular joint instabilities. The purpose of this study was to determine the impact of various implant materials following arthroscopically assisted stabilization of acromioclavicular joint instabilities on tunnel widening and implant migration. We hypothesized an implant-dependent behavior for tunnel widening and implant migration with differences when comparing acute and chronic acromioclavicular joint instabilities.

Methods: This study compared 105 patients with acromioclavicular joint instabilities that were managed operatively with coracoclavicular double button constructs. Two of the groups containing acute cases were treated with either a double button construct with a wire (TR) or a tape (D) as a central pillar. The two groups with chronic cases were either treated with a wire (T+) or tape D+ as a central pillar and additional hamstring tendon augmentation (+). One central transclavicular-transcoracoidal drill channel was made in the acute cases, while additional medial and lateral drill channels to augment the central pillar with the hamstring tendon were made. The central drill channel in all cases and the medial/lateral drill channels in chronic cases were subsequently radiologically analyzed immediately postoperatively and at follow-up. Following this, additional radiological analysis of the implant migration of the clavicular button took place.

Results: All groups showed significant tunnel widening of the central drill channel at follow-up (p ≤ 0.001). The TR+ technique demonstrated significant widening in both the medial (p ≤ 0.001) and lateral (p ≤ 0.001) drill channels. The D and D+ group displayed significant higher rates of clavicular button migration to a cortical and intraosseous level (p ≤ 0.002).

Conclusion: Tunnel widening and implant migration following arthroscopically assisted management of acromioclavicular joint instabilities are dependent on the chosen implant. The stable tape showed a significantly increased degree of tunnel widening with respect to the central drill channel in comparison with the wire. In contrast, a higher degree of load capacity of the tape ultimately favors a protected intraosseous graft healing for chronic cases, which leads to less tunnel widening of the medial and lateral drill channel. Finally, the D/D+ implant groups showed higher rates of implant migration due to lower contact surface area of the implant at the upper clavicular cortex.

Keywords: Acromioclavicular joint instabilities; Clavicular button migration; Transclavicular–transcoracoidal drilling; Tunnel widening.

MeSH terms

  • Acromioclavicular Joint* / surgery
  • Arthroscopy / adverse effects
  • Arthroscopy / methods
  • Humans
  • Joint Dislocations* / surgery
  • Joint Instability* / diagnostic imaging
  • Joint Instability* / etiology
  • Joint Instability* / surgery
  • Prostheses and Implants
  • Radiography