Exploration of thoracoabdominal aortic mixed reality optimisation and its clinical application value in type A aortic dissection

Eur Radiol. 2023 Jun;33(6):4313-4322. doi: 10.1007/s00330-022-09372-4. Epub 2023 Jan 9.

Abstract

Objectives: This study aimed to explore the feasibility of low-dose computed tomography (CT)-based mixed reality and its clinical role in type A aortic dissection (TAAD) operations.

Methods: Eighty-seven patients diagnosed with TAAD were prospectively enrolled and underwent thoracoabdominal aorta mixed reality. They were randomly divided into a low-dose mixed reality group, a conventional mixed reality group and a conventional thoracoabdominal aorta computed tomography angiography (CTA) group. Three-dimensional modelling, mixed reality and CT reconstruction technology were selected. The radiation dose and image quality were compared using Student's t test. Doctors with different seniorities evaluated the clinical application value of thoracoabdominal aorta mixed reality using a Likert scale. The consistency was assessed using the Cohen kappa coefficient (k). The Pearson chi-square test was used to test the correlation of perioperative index results in TAAD operations.

Results: Low-dose CT technology can be effectively applied to thoracoabdominal aorta mixed reality and reduces the radiation dose by approximately 59% and the operation time and auxiliary cardiopulmonary bypass time by approximately 22% and 29%, respectively. The subjective scores of doctors with different seniorities on the clinical application value of thoracoabdominal aorta mixed reality were higher than those of thoracoabdominal aorta CTA (all p > 0.05).

Conclusions: Low-dose CT can be effectively used in thoracoabdominal aortic mixed reality to reduce the radiation dose while ensuring quality. Low-dose thoracoabdominal aortic mixed reality has clinical application value and can effectively reduce the operation time and auxiliary cardiopulmonary bypass time in TAAD operations.

Key points: • Low-dose CT technology can ensure the mixed reality quality of the thoracoabdominal aorta with a radiation dose reduction of approximately 59%. • Compared with thoracoabdominal aorta CTA, low-dose thoracoabdominal aorta mixed reality can reduce the operation time and auxiliary cardiopulmonary bypass time by approximately 20% and 29%, respectively, in TAAD operations. • The application value of low-dose thoracoabdominal aorta mixed reality in operation scheme formulation, operation risk assessment, operation navigation and diagnosis and treatment under safe distance was greater than that of thoracoabdominal aorta CTA in TAAD.

Keywords: Angiography; Aortic dissection; Computed tomography angiography; Imaging, three-dimensional.

Publication types

  • Randomized Controlled Trial

MeSH terms

  • Aorta
  • Aortic Dissection* / diagnostic imaging
  • Aortic Dissection* / surgery
  • Augmented Reality*
  • Computed Tomography Angiography / methods
  • Humans

Substances

  • 1,3,4,6-tetra-O-acetyl-2-azido-2-deoxyglucopyranose