Artificial Neural Network-Assisted Classification of Hearing Prognosis of Sudden Sensorineural Hearing Loss With Vertigo

IEEE J Transl Eng Health Med. 2023 Feb 6:11:170-181. doi: 10.1109/JTEHM.2023.3242339. eCollection 2023.

Abstract

This study aimed to determine the impact on hearing prognosis of the coherent frequency with high magnitude-squared wavelet coherence (MSWC) in video head impulse test (vHIT) among patients with sudden sensorineural hearing loss with vertigo (SSNHLV) undergoing high-dose steroid treatment. This study was a retrospective cohort study. SSNHLV patients treated at our referral center from December 2016 to December 2020 were examined. The cohort comprised 64 patients with SSNHLV undergoing high-dose steroid treatment. MSWC was measured by calculating the wavelet coherence analysis (WCA) at various frequencies from a vHIT. The hearing prognosis were analyzed using a multivariable Cox regression model and convolution neural network (CNN) of WCA. There were 64 patients with a male-to-female ratio of 1:1.67. The greater highest coherent frequency of the posterior semicircular canal (SCC) was associated with the complete recovery (CR) of hearing. After adjustment for other factors, the result remained robust (hazard ratio [HR] 2.11, 95% confidence interval [CI] 1.86-2.35). In the feature extraction with Resnet-50 and proceeding SVM in the horizontal image cropping style, the classification accuracy [STD] for (CR vs. partial + no recovery [PR + NR]), (over-sampling of CR vs. PR + NR), (extensive data extraction of CR vs. PR + NR), and (interpolation of time series of CR vs. PR + NR) were 83.6% [7.4], 92.1% [6.8], 88.9% [7.5], and 91.6% [6.4], respectively. The high coherent frequency of the posterior SCC was a significantly independent factor that was associated with good hearing prognosis in the patients who have SSNHLV. WCA may be provided with comprehensive ability in vestibulo-ocular reflex (VOR) evaluation. CNN could be utilized to classify WCA, predict treatment outcomes, and facilitate vHIT interpretation. Feature extraction in CNN with proceeding SVM and horizontal cropping style of wavelet coherence plot performed better accuracy and offered more stable model for hearing outcomes in patients with SSNHLV than pure CNN classification. Clinical and Translational Impact Statement-High coherent frequency in vHIT results in good hearing outcomes in SSNHLV and facilitates AI classification.

Keywords: Artificial intelligence; hearing prognosis; sudden sensorineural hearing loss; video head impulse test; wavelet coherence.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Female
  • Hearing
  • Hearing Loss, Sensorineural*
  • Hearing Loss, Sudden*
  • Humans
  • Male
  • Prognosis
  • Retrospective Studies
  • Steroids
  • Vertigo

Substances

  • Steroids

Grants and funding

This work was supported in part by the Kaohsiung Veterans General Hospital under Grant VGHKS108-082.