Biomechanical Stability of Lateral Ulnar Collateral Ligament Reconstruction and Repair of the Elbow: The Role of Ligament Bracing on Gap Formation and Stabilization

Am J Sports Med. 2023 Apr;51(5):1303-1311. doi: 10.1177/03635465231157735. Epub 2023 Mar 6.

Abstract

Background: Augmented (internal braced) lateral ulnar collateral ligament (LUCL) repair has been biomechanically compared with reconstruction techniques in the elbow. However, LUCL repair alone has not yet been compared with augmented repair and reconstruction techniques.

Hypothesis: Internal bracing of LUCL repair would improve time-zero stabilization regarding gap formation, stiffness, and residual torque as compared with repair alone and reconstruction techniques to restore native elbow stability.

Study design: Controlled laboratory study.

Methods: Overall, 24 cadaveric elbows were used for either internal braced LUCL repair (Repair-IB) or single- and double-strand ligament reconstruction with triceps (Recon-TR) and palmaris longus tendon graft (Recon-PL), respectively. Laxity testing in external rotation was consecutively performed at 90° of elbow flexion on the intact, dissected, and repaired conditions and with the previously assigned techniques. First, intact elbows were loaded to 7.0-N·m external torque to evaluate time-zero ligament rotations at 2.5, 4.0, 5.5, and 7.0 N·m. Rotation-controlled cycling was performed (total of 1000 cycles) for each surgical condition. Gapping, stiffness, and residual torque were analyzed. Finally, these and 8 additional intact elbows underwent torque-to-failure testing (30 deg/min).

Results: The dissected state showed the highest gap formation and lowest peak torques (P < .001). While gap formation of Repair-IB (P < .021) was significantly lower than that of repair without internal bracing at all rotation levels, gaps of Recon-PL were similar to and Recon-TR were significantly higher than those of Repair-IB except for the highest torsion level. Residual peak torques at specific rotation angles between native state and Recon-TR (α2.5), Recon-PL (α4.0), and Repair-IB (α5.5) were similar; all other comparisons were significantly different (P < .027). Torsional stiffness of Repair-IB was significantly higher at all rotation angles measured. Analysis of covariance showed significantly less gap formation over residual peak torques for Repair-IB (P < .001) as compared with all other groups. The native state failure load was significantly higher than Recon-PL and Recon-TR failure loads, with similar stiffness to all other groups.

Conclusion: Repair-IB and Recon-PL of the LUCL showed increased rotational stiffness relative to the intact elbow for restoring posterolateral stability to the native state in a cadaveric model. Recon-TR demonstrated lower residual peak torques but provided near-native rotational stiffness.

Clinical relevance: Internal bracing of LUCL repair may reduce suture-tearing effects through tissue and provide sufficient stabilization for healing throughout accelerated and reliable recovery without the need for a tendon graft.

Keywords: LUCL repair; augmentation; biomechanical testing; gap formation.

MeSH terms

  • Biomechanical Phenomena
  • Cadaver
  • Collateral Ligament, Ulnar* / surgery
  • Collateral Ligaments* / surgery
  • Elbow / surgery
  • Elbow Joint* / surgery
  • Humans
  • Joint Instability* / surgery
  • Range of Motion, Articular
  • Ulnar Collateral Ligament Reconstruction* / methods