PtNPs/rGO-GluOx/mPD Directionally Electroplated Dual-Mode Microelectrode Arrays for Detecting the Synergistic Relationship between the Cortex and Hippocampus of Epileptic Rats

ACS Sens. 2023 Apr 28;8(4):1810-1818. doi: 10.1021/acssensors.3c00140. Epub 2023 Apr 4.

Abstract

Precise and directional couplings of functional nanomaterials with implantable microelectrode arrays (IMEAs) are critical for the manufacture of sensitive enzyme-based electrochemical neural sensors. However, there is a gap between the microscale of IMEA and conventional bioconjugation techniques for enzyme immobilization, which leads to a series of challenges such as limited sensitivity, signal crosstalk, and high detection voltage. Here, we developed a novel method using carboxylated graphene oxide (cGO) to directionally couple the glutamate oxidase (GluOx) biomolecules onto the neural microelectrode to monitor glutamate concentration and electrophysiology in the cortex and hippocampus of epileptic rats under RuBi-GABA modulation. The resulting glutamate IMEA exhibited good performance involving less signal crosstalk between microelectrodes, lower reaction potential (0.1 V), and higher linear sensitivity (141.00 ± 5.66 nA μM-1 mm-2). The excellent linearity ranged from 0.3 to 68 μM (R = 0.992), and the limit of detection was 0.3 μM. For epileptic rats, the proposed IMEA sensitively obtained synergetic variations in the action potential (Spike), local field potentials (LFPs), and glutamate of the cortex and hippocampus during seizure and RuBi-GABA inhibition. We found that the increase in glutamate preceded the burst of electrophysiological signals. At the same time, both changes in the hippocampus preceded the cortex. This reminded us that glutamate changes in the hippocampus could serve as important indicators for early warning of epilepsy. Our findings provided a new technical strategy for directionally stabilizing enzymes onto the IMEA with versatile implications for various biomolecules' modification and facilitated the development of detecting tools for understanding the neural mechanism.

Keywords: directional immobilization; epilepsy warning; glutamate biosensor; graphene oxide; implanted microelectrode array.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Epilepsy*
  • Glutamic Acid
  • Hippocampus* / physiology
  • Microelectrodes
  • Rats
  • Rats, Sprague-Dawley
  • gamma-Aminobutyric Acid / pharmacology

Substances

  • graphene oxide
  • Glutamic Acid
  • gamma-Aminobutyric Acid