Upper extremity kinematics during walking gait changes through pregnancy

Gait Posture. 2023 Jul:104:97-102. doi: 10.1016/j.gaitpost.2023.06.017. Epub 2023 Jun 22.

Abstract

Background: Thirty percent of adults in the United States use wearable fitness devices as of 2020 [1], such as fitness watches, to monitor and track health and physical activity parameters. Physical changes during pregnancy may impact wrist worn device accuracy. The arms may be needed as compensation during walking because thorax axial rotation may be inhibited by pelvic tilt during pregnancy [2].

Methods: To examine arm motion changes, twenty-three pregnant women (28 ± 4 y) were tested in four-week intervals ( ± 2 weeks) at 18-, 22-, 26-, 30- and 34-weeks' gestation. Kinematic data were measured during self-selected speed walking. Segment angles and angular velocities were analyzed over time. Linear regressions were used to analyze the correlations between arm motion and the other kinematic variables.

Results: Arm range of motion significantly increased (p = 0.006) over gestation, but leg, thorax, and pelvis range of motions did not significantly change. Arm range of motion was correlated with pelvis (r2 =0.311, p = 0.001, β = 1.724) and leg (r2 = 0.285, p = 0.004, β = 1.520) range of motion and gait velocity (r2 =0.566, p = 0.001, β = 39.110). Arm velocities significantly increased (p < 0.012), as did leg velocities (p < 0.022) over gestation time, but thorax and pelvis rotational velocities did not significantly change over time. Arm velocity was correlated with leg velocity in both flexion (r2 =0.598, p = 0.001, β = 1.61) and extension (r2 =0.568, p = 0.001, β = 1.35).

Significance: Arm swing increases over the course of gestation during walking, which does not follow the exact pattern of changes seen in the legs, thorax, and pelvis. These results show that a typical gait analysis of lower body motions may miss important biomechanical changes or compensations at different points over pregnancy. Future studies should examine why these changes may occur. Studies should also be conducted to see if arm changes impact outcome parameters from fitness watches and affect their validity as an exercise tracker during pregnancy.

Keywords: Arm; Gestation; Shoulder; Smart technology; Smartwatch.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Arm
  • Biomechanical Phenomena
  • Female
  • Gait*
  • Humans
  • Pelvis
  • Pregnancy
  • Range of Motion, Articular
  • Rotation
  • Walking*