Liver Cancer Vascularity Driven by Extracellular Matrix Stiffness: Implications for Imaging Research

Invest Radiol. 2023 Dec 1;58(12):894-902. doi: 10.1097/RLI.0000000000001001. Epub 2023 Jul 5.

Abstract

Background: Extracellular matrix stiffness represents a barrier to effective local and systemic drug delivery. Increasing stiffness disrupts newly formed vessel architecture and integrity, leading to tumor-like vasculature. The resulting vascular phenotypes are manifested through different cross-sectional imaging features. Contrast-enhanced studies can help elucidate the interplay between liver tumor stiffness and different vascular phenotypes.

Purpose: This study aims to correlate extracellular matrix stiffness, dynamic contrast-enhanced computed tomography, and dynamic contrast-enhancement ultrasound imaging features of 2 rat hepatocellular carcinoma tumor models.

Methods and materials: Buffalo-McA-RH7777 and Sprague Dawley (SD)-N1S1 tumor models were used to evaluate tumor stiffness by 2-dimensional shear wave elastography, along with tumor perfusion by dynamic contrast-enhanced ultrasonography and contrast-enhanced computed tomography. Atomic force microscopy was used to calculate tumor stiffness at a submicron scale. Computer-aided image analyses were performed to evaluate tumor necrosis, as well as the percentage, distribution, and thickness of CD34+ blood vessels.

Results: Distinct tissue signatures between models were observed according to the distribution of the stiffness values by 2-dimensional shear wave elastography and atomic force microscopy ( P < 0.05). Higher stiffness values were attributed to SD-N1S1 tumors, also associated with a scant microvascular network ( P ≤ 0.001). Opposite results were observed in the Buffalo-McA-RH7777 model, exhibiting lower stiffness values and richer tumor vasculature with predominantly peripheral distribution ( P = 0.03). Consistent with these findings, tumor enhancement was significantly greater in the Buffalo-McA-RH7777 tumor model than in the SD-N1S1 on both dynamic contrast-enhanced ultrasonography and contrast-enhanced computed tomography ( P < 0.005). A statistically significant positive correlation was observed between tumor perfusion on dynamic contrast-enhanced ultrasonography and contrast-enhanced computed tomography in terms of the total area under the curve and % microvessel tumor coverage ( P < 0.05).

Conclusions: The stiffness signatures translated into different tumor vascular phenotypes. Two-dimensional shear wave elastography and dynamic contrast-enhanced ultrasonography adequately depicted different stromal patterns, which resulted in unique imaging perfusion parameters with significantly greater contrast enhancement observed in softer tumors.

MeSH terms

  • Animals
  • Contrast Media
  • Elasticity Imaging Techniques* / methods
  • Extracellular Matrix / pathology
  • Liver Neoplasms* / diagnostic imaging
  • Liver Neoplasms* / pathology
  • Rats
  • Rats, Sprague-Dawley
  • Ultrasonography

Substances

  • Contrast Media