A dual-ratio fluorescent probe with a single excitation triple-signal to synchronously detect PTK7 and miRNA-21 for breast cancer early diagnosis

Biosens Bioelectron. 2023 Oct 1:237:115529. doi: 10.1016/j.bios.2023.115529. Epub 2023 Jul 11.

Abstract

The measurement of tumor biomarker levels is of great significance for early diagnosis of breast cancer. The combination diagnosis of multiple tumor biomarkers will significantly improve the accuracy of early diagnosis. Here, we successfully developed a dual-ratio fluorescent sensing platform for the detection of breast cancer biomarkers (PTK7, miRNA-21) using single excitation triple-signal detection. Introducing three types of fluorescence nanomaterials with narrow emission peaks and long Stokes shift as signal markers, the three peaks (430 nm, 530 nm and 640 nm) of which do not interfere with each other in fluorescence spectra under a single excitation (360 nm). The sensing platform linked aptamer (apt) modified green fluorescence quantum dots (gQDs-apt1) and aptamer modified red fluorescence quantum dots (rQDs-apt2) to Fe3O4-cDNA1 and Fe3O4-cDNA2, respectively, via base complementary pairing with aptamer molecules. When PTK7/miRNA-21 is present in the system, gQDs-apt1/rQDs-apt2 bound to the Fe3O4 MNPs surface will be released to recover fluorescence. Upon DNase I digestion of free apt1 and apt2, the target molecules will be released to bind to gQDs-apt1/rQDs-apt2 for signal amplification. After magnetic separation, PTK7 and miRNA-21 can be quantified using the fluorescence intensity ratio of gQDs with bCDs and rQDs with bCDs at a single excitation of 360 nm wavelength. This method has high sensitivity, good selectivity, and can quantify both PTK7 and miRNA-21 simultaneously with an LOD of 0.426 ng mL-1 and 0.072 nM, respectively. Additionally, the sensing platform was used for serum detection of health man and breast cancer patients with satisfactory results.

Keywords: Dual-ratio fluorescent probe; Enzyme amplification; PTK7; Synchronous detection; miRNA-21.

MeSH terms

  • Aptamers, Nucleotide*
  • Biomarkers, Tumor
  • Biosensing Techniques*
  • Breast Neoplasms* / diagnosis
  • Breast Neoplasms* / genetics
  • Cell Adhesion Molecules
  • Early Detection of Cancer
  • Female
  • Fluorescent Dyes
  • Humans
  • MicroRNAs*
  • Quantum Dots*
  • Receptor Protein-Tyrosine Kinases

Substances

  • Fluorescent Dyes
  • Biomarkers, Tumor
  • Aptamers, Nucleotide
  • MicroRNAs
  • PTK7 protein, human
  • Cell Adhesion Molecules
  • Receptor Protein-Tyrosine Kinases
  • MIRN21 microRNA, human