Implantable arterial doppler efficacy in free flap reconstruction: A systematic review and meta-analysis

Head Neck. 2023 Oct;45(10):2710-2717. doi: 10.1002/hed.27500. Epub 2023 Aug 29.

Abstract

The implantable arterial doppler (IAD) is frequently used to postoperatively monitor free flaps with high accuracy, but there are no guidelines for its use. Bedside exam is used adjunctively to determine necessary intervention. This systematic review seeks to discover why the doppler is used adjunctively despite its established record of accuracy. Criteria for inclusion and exclusion were established. In total, 280 articles were found on PubMed and Web of Science, then screened accordingly. Data from 22 articles were analyzed using a bivariate hierarchical random effects model. Twenty-two studies yielded 2996 total patients undergoing 3127 free flap procedures. The meta-analysis found a high sensitivity of 0.809 (95% CI = 0.709, 0.880) and specificity of 0.966 (95% CI = 0.947, 0.979). False-positive rate was found to be 0.034 (95% CI = 0.021, 0.053). Positive and negative predictive values were 0.711 (95% CI = 0.581, 0.817) and 0.979 (95% CI = 0.966, 0.988). Positive and negative likelihood ratios were 24.7 (95% CI = 14.5, 39.5) and 0.20 (95% CI = 0.12, 0.30). The established efficacy of the IAD is supported by this study. Clinical exams may remain as the final adjunct due to the risks of inaccurate IAD signals. Further studies are warranted to optimize its use for future practice guidelines.

Keywords: flap monitoring; free flap; implantable doppler; microvascular surgery; systematic review.

Publication types

  • Meta-Analysis
  • Systematic Review
  • Review

MeSH terms

  • Arteries
  • Free Tissue Flaps*
  • Humans
  • Plastic Surgery Procedures*
  • Prostheses and Implants
  • Ultrasonography, Doppler