Background: Spinal manipulation (SM) is a recommended and effective treatment for musculoskeletal disorders. Biomechanical (kinetic) parameters (e.g. preload/peak force, rate of force application and thrust duration) can be measured during SM, quantifying the intervention. Understanding these force-time characteristics is the first step towards identifying possible active ingredient/s responsible for the clinical effectiveness of SM. Few studies have quantified SM force-time characteristics and with considerable heterogeneity evident, interpretation of findings is difficult. The aim of this study was to synthesise the literature describing force-time characteristics of manual SM.
Methods: This scoping literature review is reported following the Preferred Reporting Items for Scoping Reviews (PRISMA-ScR) statement. Databases were searched from inception to October 2022: MEDLINE (Ovid), Embase, CINAHL, ICL, PEDro and Cochrane Library. The following search terms and their derivatives were adapted for each platform: spine, spinal, manipulation, mobilization or mobilisation, musculoskeletal, chiropractic, osteopathy, physiotherapy, naprapathy, force, motor skill, biomechanics, dosage, dose-response, education, performance, psychomotor, back, neck, spine, thoracic, lumbar, pelvic, cervical and sacral. Data were extracted and reported descriptively for the following domains: general study characteristics, number of and characteristics of individuals who delivered/received SM, region treated, equipment used and force-time characteristics of SM.
Results: Of 7,607 records identified, 66 (0.9%) fulfilled the eligibility criteria and were included in the analysis. Of these, SM was delivered to the cervical spine in 12 (18.2%), the thoracic spine in 40 (60.6%) and the lumbopelvic spine in 19 (28.8%) studies. In 6 (9.1%) studies, the spinal region was not specified. For SM applied to all spinal regions, force-time characteristics were: preload force (range: 0-671N); peak force (17-1213N); rate of force application (202-8700N/s); time to peak thrust force (12-938ms); and thrust duration (36-2876ms).
Conclusions: Considerable variability in the reported kinetic force-time characteristics of SM exists. Some of this variability is likely due to differences in SM delivery (e.g. different clinicians) and the measurement equipment used to quantify force-time characteristics. However, improved reporting in certain key areas could facilitate more sophisticated syntheses of force-time characteristics data in the future. Such syntheses could provide the foundation upon which dose-response estimates regarding the clinical effectiveness of SM are made.
Keywords: Biomechanics; Force-time characteristics; Kinematics; Kinetics; Spinal manipulation; Spine Pain.
© 2023. Chiropractic and Osteopathic College of Australasia, European Academy of Chiropractic, The Royal College of Chiropractors, Nordic Institute of Chiropractic and Clinical Biomechanics and BioMed Central Ltd.