Four-Year Outcomes of Cementless Versus Cemented Fixation of a Newly Introduced Total Knee Arthroplasty Design

Orthopedics. 2024 May-Jun;47(3):161-166. doi: 10.3928/01477447-20240122-02. Epub 2024 Jan 25.

Abstract

Background: Aseptic loosening continues to be a major cause of failure of total knee arthroplasty (TKA). Although cemented fixation remains the gold standard, there is renewed interest in cementless fixation as a means of decreasing this risk via biologic fixation. The purpose of this study was to evaluate the clinical outcomes of cemented and cementless versions of a newly introduced TKA design at an average of 4 years postoperatively.

Materials and methods: This was a retrospective case-control study of 100 primary TKAs comparing cementless vs cemented TKAs using the same cruciate-retaining implant design (ATTUNE Knee System; DePuy Synthes). Fifty patients undergoing cementless TKA with a mean age of 60.8 years (range, 48-71 years) and body mass index (BMI) of 31.6 kg/m2 (range, 23.7-41.9 kg/m2) were matched to 50 patients undergoing primary cemented TKA with a mean age of 62.7 years (range, 51-73 years) and BMI of 30.1 kg/m2 (range, 24.6-43.9 kg/m2). The mean follow-up was 4.2 years (range, 4.0-4.4 years) in the cementless group and 7.6 years (range, 7.5-7.7 years) in the cemented group. Complications, clinical outcomes using the Knee Society Score (KSS), and radiographic analyses were evaluated at final follow-up. Student's t tests were used for statistical analyses.

Results: There was no statistical difference in age, BMI, and preoperative KSS between the two groups (P=.12, P=.15, and P=.55, respectively). There were no complications or reoperations in either cohort. There were no statistical differences in range of motion and total KSS at final follow-up between the two groups. Final total KSS had a mean of 91.1 for the cementless group and 93.7 for the cemented group. There was no radiographic evidence of component subsidence or loosening in either cohort.

Conclusion: When compared with its cemented counterpart, the newly introduced cementless TKA design had similar excellent clinical improvements and radiologic results at an average of 4 years of follow-up. [Orthopedics. 2024;47(3):161-166.].

Publication types

  • Comparative Study

MeSH terms

  • Aged
  • Arthroplasty, Replacement, Knee* / instrumentation
  • Arthroplasty, Replacement, Knee* / methods
  • Bone Cements / therapeutic use
  • Case-Control Studies
  • Female
  • Humans
  • Knee Prosthesis*
  • Male
  • Middle Aged
  • Prosthesis Design*
  • Prosthesis Failure