Retrograde Flow Into the Internal Jugular Vein in a Hemodialysis Patient Mimicking Dural Arteriovenous Fistula: A Case Report

Cureus. 2024 Jan 28;16(1):e53092. doi: 10.7759/cureus.53092. eCollection 2024 Jan.

Abstract

Arterial spin labeling (ASL) and three-dimensional (3D) time-of-flight (TOF) magnetic resonance angiography (MRA) are sensitive tools to detect dural arteriovenous fistula (DAVF), but hyperintensity in these images is also caused by jugular venous reflux. We present a case of a patient with renal failure on hemodialysis with retrograde flow into the internal jugular vein (IJV) mimicking DAVF. A 74-year-old man with a radial arteriovenous fistula for hemodialysis experienced transient dizziness. The TOF MRA and ASL revealed high signal intensity, suggesting the presence of a DAVF in the left transverse and sigmoid sinuses and the IJV. Digital subtraction angiography (DSA) revealed no evidence of a DAVF but showed retrograde flow into the IJV via his radial shunt. In hemodialysis patients, a high-flow shunt can cause fast retrograde flow into the dural sinuses and might lead to intracranial hypertension. The ASL images are useful for early detection and careful observation.

Keywords: arterial spin labeling (asl); arteriovenous graft fistula; dural arteriovenous fistula (davf); hemodialysis complication; intracranial dural arteriovenous fistula; jugular valve disfunction; jugular vein reflux.

Publication types

  • Case Reports