Leadless Pacemaker Implantation from the Jugular Vein Ipsilateral to the Dialysis Catheter: Last Resort for Patients with Limited Vascular Routes

Can J Cardiol. 2024 Mar 15:S0828-282X(24)00206-X. doi: 10.1016/j.cjca.2024.03.006. Online ahead of print.

Abstract

In patients with end-stage renal disease (ESRD), bloodstream infections and vascular access problems are frequently encountered, and patient management is critical if a cardiac implantable electronic device (CIED) infection develops in a pacing-dependent patient. Here, we describe a case of an ESRD patient with a device infection in whom a leadless pacemaker (LP) implantation from the jugular vein ipsilateral to the dialysis catheter (DC) was successful.

Keywords: dialysis catheter; jugular approach; leadless pacemaker.

Publication types

  • Case Reports