Comparison of the S8 navigation system and the TINAVI orthopaedic robot in the treatment of upper cervical instability

Sci Rep. 2024 Mar 18;14(1):6487. doi: 10.1038/s41598-024-55610-8.

Abstract

The objective is to compare the clinical efficacy and safety of the S8 navigation system and the Tinavi orthopaedic surgery robot in the treatment of upper cervical instability. The research methods adopted are as follows. The clinical data of patients with upper cervical instability who underwent surgery from May 2021 to December 2021 were analysed retrospectively. Patients were divided into a navigation group (assisted by the S8 navigation system) and a tinavi group (assisted by the Tinavi robot) according to the auxiliary system used. Computed tomography and digital radiography were performed after the operation. The accuracy of pedicle screw placement was evaluated using the criteria put forward by Rampersaud. Degree of facet joint violation, visual analogue scale score, neck disability index and Japanese orthopaedic association score were recorded and assessed during follow-up examinations in both groups. Record two groups of surgery-related indicators. Record the complications of the two groups. A total of 50 patients were included. 21 patients in the navigation group and 29 in the tinavi group. The results of the study are as follows. The average follow-up time was 12.1 months. There was no significant difference in nail placement accuracy between the navigation and tinavi groups (P > 0.05); however, the navigation group had a significantly higher rate of facet joint violation than that of tinavi group (P < 0.05), and the screws were placed closer to the anterior cortex (P < 0.05). Significantly more intraoperative fluoroscopies were performed in the tinavi group than in the navigation group, and the operation time was significantly longer in the tinavi group than in the navigation group (P < 0.05). The time of single nail implantation, intraoperative blood loss and incision length in navigation group were significantly longer than those in tinavi group. There were no statistically significant differences in other indicators between the two groups (P > 0.05). We come to the following conclusion. The Stealth Station S8 navigation system (Medtronic, USA), which also uses an optical tracking system, and the Tinavi Orthopedic robot have shown the same high accuracy and satisfactory clinical results in the treatment of upper cervical instability. Although the S8 navigation system still has many limitations, it still has good application prospects and is a new tool for spine surgery.

Keywords: 3D real-time navigation system; O-arm; Tinavi robot; Upper cervical vertebra instability.

MeSH terms

  • Humans
  • Orthopedics*
  • Pedicle Screws*
  • Retrospective Studies
  • Robotics*
  • Spinal Fusion*
  • Treatment Outcome