Accuracy of Diagnosing Heparin-Induced Thrombocytopenia
- PMID: 38530310
- PMCID: PMC10966416
- DOI: 10.1001/jamanetworkopen.2024.3786
Accuracy of Diagnosing Heparin-Induced Thrombocytopenia
Abstract
Importance: Heparin-induced thrombocytopenia (HIT) is a life-threatening condition that requires urgent diagnostic clarification. However, knowledge of the diagnostic utility of the recommended diagnostic tests is limited in clinical practice.
Objective: To evaluate the current diagnostic practice for managing the suspicion of HIT.
Design, setting, and participants: This prospective diagnostic study was conducted from January 2018 to May 2021 among consecutive patients with suspected HIT from 11 study centers in Switzerland, Germany, and the United States. Detailed clinical data and laboratory information were recorded. Platelet factor 4/heparin antibodies were quantified using an automated chemiluminescent immunoassay (CLIA). A washed-platelet heparin-induced platelet activation (HIPA) test was used as a reference standard to define HIT.
Exposures: Suspicion of HIT.
Main outcomes and measures: The primary outcome was the diagnostic accuracy of the 4Ts score, the CLIA, and the recommended algorithm serially combining both tests.
Results: Of 1448 patients included between 2018 and 2021, 1318 were available for the current analysis (median [IQR] age, 67 [57-75] years; 849 [64.6%] male). HIPA was positive in 111 patients (prevalence, 8.4%). The most frequent setting was intensive care unit (487 [37.0%]) or cardiovascular surgery (434 [33.0%]). The 4Ts score was low risk in 625 patients (46.8%). By 2 × 2 table, the numbers of patients with false-negative results were 10 (9.0%; 4Ts score), 5 (4.5%; CLIA), and 15 (13.5%; recommended diagnostic algorithm). The numbers of patients with false-positive results were 592 (49.0%; 4Ts score), 73 (6.0%; CLIA), and 50 (4.1%; recommended diagnostic algorithm), respectively.
Conclusions and relevance: In this diagnostic study of patients suspected of having HIT, when the recommended diagnostic algorithm was used in clinical practice, antibody testing was required in half the patients. A substantial number of patients were, however, still misclassified, which could lead to delayed diagnosis or overtreatment. Development of improved diagnostic algorithms for HIT diagnosis should be pursued.
Conflict of interest statement
Figures
Similar articles
-
Combination of 2 Quantitative Immunoassays and Clinical Score Algorithm to Reduce False-Negative Results in Heparin-Induced Thrombocytopenia: Prevalence Study of Mauriziano Hospital in Turin, Italy.J Appl Lab Med. 2024 Sep 3;9(5):940-951. doi: 10.1093/jalm/jfae062. J Appl Lab Med. 2024. PMID: 38980803
-
Evaluating Diagnostic Algorithms for Heparin-Induced Thrombocytopenia using Two Combined Automated Rapid Immunoassays.Semin Thromb Hemost. 2024 Nov;50(8):1123-1130. doi: 10.1055/s-0044-1786749. Epub 2024 May 11. Semin Thromb Hemost. 2024. PMID: 38733981
-
A machine-learning model for reducing misdiagnosis in heparin-induced thrombocytopenia: A prospective, multicenter, observational study.EClinicalMedicine. 2022 Nov 24;55:101745. doi: 10.1016/j.eclinm.2022.101745. eCollection 2023 Jan. EClinicalMedicine. 2022. PMID: 36457646 Free PMC article.
-
Diagnosing heparin-induced thrombocytopenia: The need for accuracy and speed.Int J Lab Hematol. 2021 Jul;43 Suppl 1:96-102. doi: 10.1111/ijlh.13564. Int J Lab Hematol. 2021. PMID: 34288442 Review.
-
An update on evidence based diagnostic and confirmatory testing strategies for heparin induced thrombocytopenia using combined immunological and functional assays.Transfus Apher Sci. 2018 Dec;57(6):804-811. doi: 10.1016/j.transci.2018.10.019. Epub 2018 Oct 30. Transfus Apher Sci. 2018. PMID: 30401517 Review.
References
-
- Nand S, Wong W, Yuen B, Yetter A, Schmulbach E, Gross Fisher S. Heparin-induced thrombocytopenia with thrombosis: incidence, analysis of risk factors, and clinical outcomes in 108 consecutive patients treated at a single institution. Am J Hematol. 1997;56(1):12-16. doi:10.1002/(SICI)1096-8652(199709)56:1<12::AID-AJH3>3.0.CO;2-5 - DOI - PubMed