Is mesh pore size in polypropylene meshes associated with the outcome in Lichtenstein inguinal hernia repair: a registry-based analysis of 22,141 patients

Hernia. 2024 May 1. doi: 10.1007/s10029-024-03029-5. Online ahead of print.

Abstract

Introduction: Experimental data show that large-pored meshes reduce foreign body reaction, inflammation and scar bridging and thus improve mesh integration. However, clinical data on the effect of mesh porosity on the outcome of hernioplasty are limited. This study investigated the relation of pore size in polypropylene meshes to the outcome of Lichtenstein inguinal hernioplasty using data from the Herniamed registry.

Methods: This analysis of data from the Herniamed registry evaluated perioperative and 1-year follow-up outcomes in patients undergoing elective, primary, unilateral Lichtenstein inguinal hernia repair using polypropylene meshes. Patients operated with a non-polypropylene mesh or a polypropylene mesh with absorbable components were excluded. Polypropylene meshes with a pore size of 1.0 × 1.0 mm or less were defined as small-pored meshes, while a pore size of more than 1.0 × 1.0 mm was considered large-pored. Unadjusted analyses and multivariable analyses were performed to investigate the relation of pore size of polypropylene meshes, patient and surgical characteristics to the outcome parameters.

Results: Data from 22,141 patients were analyzed, of which 6853 (31%) were operated on with a small-pore polypropylene mesh and 15,288 (69%) with a large-pore polypropylene mesh. No association of mesh pore size with intraoperative, general or postoperative complications, recurrence rate or pain requiring treatment was found at 1-year follow-up. A lower risk of complication-related reoperation tended to be associated with small-pore size (p = 0.086). Furthermore, small-pore mesh repair was associated with a lower risk of pain at rest and pain on exertion at 1-year follow-up.

Conclusion: The present study could not demonstrate an advantage of large-pore polypropylene meshes for the outcome of Lichtenstein inguinal hernioplasty.

Keywords: Chronic pain; Hernia recurrence; Inguinal hernia; Lichtenstein hernioplasty; Mesh pore size; Outcome hernia repair.