Single patch technique for aortic annulus reconstruction in prosthetic valve endocarditis

Multimed Man Cardiothorac Surg. 2024 May 24:2024. doi: 10.1510/mmcts.2024.014.

Abstract

Aortic root reconstruction during aortic root replacement for a patient with prosthetic valve endocarditis and aortic root abscess can be a difficult procedure with many possible complications. In this video case report, we describe our novel technique using a single bovine pericardial patch that avoids deep stitches or external sutures to support the friable annulus. Compared with more standard methods, this approach has shorter cross-clamp and cardiopulmonary bypass times and is less demanding technically.

Keywords: Infective endocarditis; Patch repair; Prosthetic valve endocarditis; Redo aortic root replacement.

Publication types

  • Video-Audio Media
  • Case Reports

MeSH terms

  • Aged
  • Animals
  • Aortic Valve* / surgery
  • Cattle
  • Endocarditis / surgery
  • Endocarditis, Bacterial / diagnosis
  • Endocarditis, Bacterial / surgery
  • Heart Valve Prosthesis Implantation / methods
  • Heart Valve Prosthesis*
  • Humans
  • Male
  • Pericardium / transplantation
  • Plastic Surgery Procedures / methods
  • Prosthesis-Related Infections / diagnosis
  • Prosthesis-Related Infections / etiology
  • Prosthesis-Related Infections / surgery